Location

These units are intended for indoor use only.  Be sure the location 

chosen has a floor strong enough to support the total weight of the 

cabinet and contents. A fully loaded 72” long model may weigh as 

much as 1200 pounds. Reinforce the floor as necessary to provide 

for maximum loading.

For the most efficient refrigeration, be sure to provide good air 

circulation inside and out.

Inside cabinet

: Do not pack refrigerator so full that air cannot 

circulate.

Outside cabinet: 

Be sure that the unit has access to ample air. Avoid 

hot corners and locations near stoves and ovens.

It is recommended that the unit be installed no closer than 1” from 

any wall. PDL models also require 14” (36cm) clearance at the top 

and 6” (15cm) clearance at the bottom (casters).

Leveling

A level cabinet looks better and will perform better because the drain 

pan will drain properly, the doors will line up with the frames properly, 

and the cabinet will not be subject to undue strain.

Some models have casters for your convenience, for ease of cleaning 

underneath and for mobility. It is important that the unit be installed 

in a stable condition with the front casters locked before operating.

Plumbing

Self-contained models are standard with a condensate evaporator. If, 

for some reason, a unit does not have a condensate evaporator, or the 

evaporator fails, the unit’s drain must have an outlet to an appropriate 

drainage area or container.

Moisture collecting from improper drainage can create 

a slippery surface on the floor and a hazard to 

employees. It is the owner’s responsibility to provide 

a container or outlet for drainage.

Electrical connection

Refer to the amperage data, the serial tag, your local code or the 

National Electrical Code to be sure the unit is connected to the proper 

power source. A protected circuit of the correct voltage and amperage 

must be run for con nec tion of the line cord, or permanent connection 

to the unit.

The power switch must be turned to OFF and the 

unit disconnected from the power source whenever 

performing service or maintenance functions.

Never operate the unit without the louvered panel in 

place!

CAUTION

DANGER

Installation

Summary of Contents for 18600 Series

Page 1: ...r 9291455 06 16 18600 Series CTP NB Original Instructions Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the late...

Page 2: ...Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety WARNING This Appliance Is Not To Be Played With WARNING Do Not Clean With Water Jet...

Page 3: ...damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier Notification shoul...

Page 4: ...re used in Delfield equipment 2016 The Delfield Company All rights reserved Reproduction without written permission is prohibited Delfield is a registered trademark of The Delfield Company Serial Numb...

Page 5: ...Load LBS Shelf Area FT2 Volume FT3 BTU Load Base Rail BTU Sys Cap Base Rail H P Voltz Hertz Phase Amps NEMA Plug Ship Weight LBS KG 18648BSTM 1 27 1 124 3 95 10 23 475 NA 1462 NA 1 5 115 60 1 8 0 5 1...

Page 6: ...TBM PTL 32 oz 907g 186114 PTBM 48 oz 1361g 18648 BUCM BSTM 16 oz 454g 18660 BUCM BSTM 16 oz 454g 18672 BUCM BSTM 16 oz 454g 18691 BUCM BSTM 16 oz 454g 18699 BUCM BSTM 24 oz 680g 186114 BUCM BSTM 24 oz...

Page 7: ...A 1 2 40 1134 230 240 50 1 5 3 594 269 186114BUC E 4 61 0cm 4 48 13434 1055 1373 NA 2591 NA 3 4 48 1361 230 240 50 1 5 0 685 310 18600BST E Work table with backsplash Custom Model Of Doors Of Shelves...

Page 8: ...undue strain Some models have casters for your convenience for ease of cleaning underneath and for mobility It is important that the unit be installed in a stable condition with the front casters loc...

Page 9: ...of a condenser fan failure or a plugged or blocked condenser this device may shut down the refrigeration system This device will automatically reset but determining the cause of the high pressure con...

Page 10: ...perature ranges for the raised rails are 33 F to 41 F 0 5 C to 5 C Product located in the rails must be removed at the end of day This allows you to turn the rails off at night to save energy and the...

Page 11: ...ncremental adjustments if a temperature adjustment is necessary It may take an hour or longer to realize the temperature change depending on the application and location of the unit Please contact Kit...

Page 12: ...fety clip must remain pushed towards the back Lift up and slide the drawer track all the way into the drawer cage The blue safety clip will lock in place automatically Once all tracks are replaced ins...

Page 13: ...rior of the cabinet or to the blower coil Overloading the storage area restricting the airflow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain ope...

Page 14: ...bracket with a bend at the back and the other to the outside 2 Place each bracket back against the rail and flush against the outside edge 3 Mark the bracket hole locations 4 Drill each 0 125 hole 5 S...

Page 15: ...18600 and CTP NB Series Service and Installation Manual 15 Notes...

Page 16: ...mprovement may necessitate change of specifications without notice Part Number 9291455 06 16 Every new piece of Manitowoc Foodservice equipment comes with KitchenCare and you choose the level of servi...

Reviews: