background image

18600 and CTP-NB Series Service and Installation Manual

3

Receiving & Inspecting Equipment ...........................................3
Serial Number Information ........................................................4
Warranty Information .................................................................4
Regulatory Certifications ............................................................4
Domestic Specifications .............................................................5
Domestic Refrigerant Charges ...................................................6
Export Specifications .................................................................7
Installation  .................................................................................8
Operation 
  18600PTB & PTL Series .........................................................9
  18600BUC & BST Series ........................................................9
  18600PDL Series ..................................................................10
  CTP-NB Series ......................................................................10
Pressure Control Settings ........................................................11
Temperature Control Settings ..................................................11
Care And Cleaning ...............................................................12-13
18600PTB Cutting Board Installation ......................................14
Notes ........................................................................................15

Contents

Receiving And Inspecting The Equipment

Even though most equipment is shipped crated, care should be 

taken during unloading so the equipment is not damaged while 

being moved into the building.

1.  Visually inspect the exterior of the package and skid or  

container.  Any damage should be noted and reported to 

the delivering carrier immediately.

2.  If damaged, open and inspect the contents with the 

carrier.

3.  In the event that the exterior is not damaged, yet upon 

opening, there is concealed damage to the equipment 

notify the carrier.  Notification should be made verbally as 

well as in written form.

4.  Request an inspection by the shipping company of the 

damaged equipment.  This should be done within 10 days 

from receipt of the equipment.

5.  Check the lower portion of the unit to be sure legs or 

casters are not bent.

6.  Also open the compressor compartment housing and 

visually inspect the refrigeration package.  Be sure lines 

are secure and base is still intact.

7.  Freight carriers can supply the necessary damage forms 

upon request.

8.  Retain all crating material until an inspection has been 

made or waived.

Uncrating the Equipment

First cut and remove the banding from around the crate.  

Remove the front of the crate material, use of some tools will 

be required.  If the unit is on legs remove the top of the crate  

and lift the unit off the skid.  If the unit is on casters it can be 

"rolled" off the skid.

Summary of Contents for 18600 Series

Page 1: ...r 9291455 06 16 18600 Series CTP NB Original Instructions Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the late...

Page 2: ...Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety WARNING This Appliance Is Not To Be Played With WARNING Do Not Clean With Water Jet...

Page 3: ...damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier Notification shoul...

Page 4: ...re used in Delfield equipment 2016 The Delfield Company All rights reserved Reproduction without written permission is prohibited Delfield is a registered trademark of The Delfield Company Serial Numb...

Page 5: ...Load LBS Shelf Area FT2 Volume FT3 BTU Load Base Rail BTU Sys Cap Base Rail H P Voltz Hertz Phase Amps NEMA Plug Ship Weight LBS KG 18648BSTM 1 27 1 124 3 95 10 23 475 NA 1462 NA 1 5 115 60 1 8 0 5 1...

Page 6: ...TBM PTL 32 oz 907g 186114 PTBM 48 oz 1361g 18648 BUCM BSTM 16 oz 454g 18660 BUCM BSTM 16 oz 454g 18672 BUCM BSTM 16 oz 454g 18691 BUCM BSTM 16 oz 454g 18699 BUCM BSTM 24 oz 680g 186114 BUCM BSTM 24 oz...

Page 7: ...A 1 2 40 1134 230 240 50 1 5 3 594 269 186114BUC E 4 61 0cm 4 48 13434 1055 1373 NA 2591 NA 3 4 48 1361 230 240 50 1 5 0 685 310 18600BST E Work table with backsplash Custom Model Of Doors Of Shelves...

Page 8: ...undue strain Some models have casters for your convenience for ease of cleaning underneath and for mobility It is important that the unit be installed in a stable condition with the front casters loc...

Page 9: ...of a condenser fan failure or a plugged or blocked condenser this device may shut down the refrigeration system This device will automatically reset but determining the cause of the high pressure con...

Page 10: ...perature ranges for the raised rails are 33 F to 41 F 0 5 C to 5 C Product located in the rails must be removed at the end of day This allows you to turn the rails off at night to save energy and the...

Page 11: ...ncremental adjustments if a temperature adjustment is necessary It may take an hour or longer to realize the temperature change depending on the application and location of the unit Please contact Kit...

Page 12: ...fety clip must remain pushed towards the back Lift up and slide the drawer track all the way into the drawer cage The blue safety clip will lock in place automatically Once all tracks are replaced ins...

Page 13: ...rior of the cabinet or to the blower coil Overloading the storage area restricting the airflow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain ope...

Page 14: ...bracket with a bend at the back and the other to the outside 2 Place each bracket back against the rail and flush against the outside edge 3 Mark the bracket hole locations 4 Drill each 0 125 hole 5 S...

Page 15: ...18600 and CTP NB Series Service and Installation Manual 15 Notes...

Page 16: ...mprovement may necessitate change of specifications without notice Part Number 9291455 06 16 Every new piece of Manitowoc Foodservice equipment comes with KitchenCare and you choose the level of servi...

Reviews: