Delem
V0208, 2.33
Range
: -999 - 0
Unit
: mm
Default
: 0
Remark
This parameter must be programmed when ‘stroke mode’ is set to 1.
Function
This is the stroke distance when the blade is positioned on the upper dead point. Stroke
position zero is defined as the upper side of the table, the minimum stroke is always negative
Parameter 88
Maximum stroke
Range
: 0 - 999
Unit
: mm
Default
: 0
Remark
This parameter must be programmed when ‘stroke mode’ is set to 1.
Function
This is the actual stroke distance, starting at the edge of the table.
Parameter 89
Stroke time
Range
: 0 - 9999
Unit
: msec
Default
: 0
Remark
This parameter must be programmed when ‘stroke mode’ is set to 1.
Function
This is the time necessary to reach the maximum stroke length, as programmed at parameter
86. When that programmed time has elapsed, the output EOS will become active.
The user can program the desired stroke length as a percentage (0-100%) of the maximum
stroke length. This percentage value can be programmed in every step with the Stroke length
parameter.
Parameter 90
Stroke reference table
Range
: -
Unit
: -
Default
: -
Function
Press ENTER to open a screen with the Stroke reference table. In this table, the relation
between stroke length and feedback voltage (input SFB) can be programmed.