Delem
V0208, 2.17
Range
: 0.0 – 9999.9
Unit
: mm
Default
: 0.0
Remark
Only if ‘Retract programmable’ (36) is set to 1.
Function
Default value for the retract distance when a new program is created.
Parameter 41
Safety Zone
Range
: 0.0 – 9999.9
Unit
: mm
Default
: 0.0
Function
Safety zone for the X-axis.
If programmed to 0, this feature is not used.
If programmed higher than 0, this parameter defines a safety zone for the X-axis. During a cut,
the X-axis should stay outside the zone to avoid collision.
The output XSAFE is used to indicate the X-axis status:
- TRUE if the X-axis is outside the zone (X > Safety zone);
- FALSE if the X-axis is inside the zone (X < Safety Zone).
Parameter 42
Spindle allowance
Range
: 0 - 1
Unit
: -
Default
: 1
Function
0 = one-side positioning
1 = two-side positioning (default)
In case of two-side positioning, the axis always moves directly to the programmed position.
The one-side positioning can be selected to overcome mechanical tolerances with two side
positioning. In case of one-side positioning the positioning direction is from a larger to a
smaller position. See also chapter 1 about drive types.
Parameter 43
Overrun
Range
: 0 - 9999
Unit
: mm
Default
: 1