After Sales Care and Technical Support:
For the UK market only: Tel.
01491 821 821 -
email:
For all other markets: Tel.
+33 (0)3 22 60 22 74 -
email:
The installation guide is available on: www.delabie.com
Product conforms to current European Directives.
MAINTENANCE
• Mixer: regularly check (as often as necessary) the temperature selector and the mixer's two internal
seats on which the mixing key turns. Replace as necessary.
Replacing the solenoid valve:
• Shut-off the hot and cold water supply.
•
Deck-mounted models and wall-mounted TEMPOMATIC 4:
loosen the screw
k
(fig.
E
) using
a 2.5mm Allen key without removing it totally, and remove the cap
m
(fig.
E
) by rotating slightly
downwards.
•
Wall-mounted TEMPOMATIC 3:
Loosen the screw
l
(fig.
F
) using a 2.5mm Allen key without
removing it totally, and remove the spout (fig.
F
).
• Remove the electronic unit
n
(fig.
E
,
F
) and disconnect the connector
o
(fig.
E
,
F
) and for mains
supply models, disconnect the electrical connectors
t
then
(fig.
I
).
• Using a 17mm socket
p
(fig.
E
,
F
) for TEMPOMATIC 3, and 13mm for TEMPOMATIC 4, unscrew the
solenoid valve
q
(fig.
E
,
F
).
• Install the new solenoid valve and carefully tighten, ensuring that the thread is not damaged.
• Reconnect the connector
o
(fig.
E
,
F
) to the electronic unit without replacing the unit.
• Reconnect the water supply and check that the valve opens/closes by activating the electronic cell.
Check that the solenoid valve is watertight inside the mixer body. If there are any leaks, gently tighten
the solenoid valve.
• Replace the electronic unit and the cap.
•
Deck-mounted models and wall-mounted TEMPOMATIC 4:
Carefully tighten the screw
k
(fig.
E
).
•
Wall-mounted TEMPOMATIC 3 mural:
Carefully tighten the screws
l
(fig.
F
) on the wall-mounted
TEMPOMATIC 3.
Replacing the 6V Lithium battery 223 (CR-P2):
•
Using a 2.5mm Allen key: loosen the screws
k
(fig.
G
,
H
) without fully removing them
and remove the cap
m
(fig.
G
,
H
) by rotating slightly downwards.
• Remove the electronic unit
n
(fig.
G
,
H
).
• Loosen the screw/s
s
(fig.
G
,
H
) (1 screw on the TEMPOMATIC 3, 2 screws on the TEMPOMATIC 4)
to change the battery, leaving the washer in place.
• Replace the assembly, carefully tightening the screws
k
(fig.
G
,
H
) (taking care not to damage the sensor).
21
EN