ADJUSTING THE TEMPERATURE
The flow rate is pre-set at the factory at 3 lpm (at 3 bar). Adjust directly on the flow straightener
(with adjustable flow rate) using a 2.5mm Allen key:
- notch n°1 = 3 lpm (at 3 bar).
- notch n°2 = 4 lpm (at 3 bar).
- notch n°3 = 5 lpm (at 3 bar).
REMEMBER
•
Our mixers/taps must be installed by professional installers
in accordance with current
regulations and recommendations in your country, and the specifications of the fluid engineer.
•
Sizing the pipes correctly
will avoid problems of flow rate, pressure loss and unwanted noise
(see calculation table in the brochure and online at www.delabie.com).
•
Protect the installation
with filters, water-hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure: 1 to 5 bar).
•
Install stopcocks
close to the mixer to facilitate maintenance.
• The pipework, stopcocks, bib taps and all sanitary fittings should be checked at least once a year,
and more frequently if necessary.
MAINTENANCE AND CLEANING
•
Cleaning chrome
Do not use abrasive, chlorine or acid-based cleaning products. Clean with soapy water using a cloth
or a sponge.
•
Frost protection
Drain the pipes and operate the mixer several times to drain any remaining water.