DEL Clean Ozone Laundry Systems
Installation & Operations Manual
10
B1. Location
The Ozone Generator is designed for wall
mounting. See fi gure 7. Mount generator in a
clean, protected area, either indoors or outdoors.
It can also be mounted to the fl oor or deck with
optional feet. Locate generator out of reach of
sprinklers or drainage spouts. Allow suffi cient access
for maintenance and all tubing and electrical wires.
Ozone generator should be installed no less than
one foot above the maximum water level.
B2. Mounting
B2.1.
Wall
Mount
B2.1.1.
Attach the Wall Mounting Brackets to the
base and top of the enclosure using the four 1/4"
x 1" long bolts and washers provided.
B2.1.2.
Refer to Figure 7
. Mark the locations for
the four mounting bolts and install anchors (not
included) appropriate for the mounting surface.
B2.1.3.
Install the four mounting bolts through the
Wall Mounting Brackets and into the anchors.
B2.2. Floor Mounting (optional)
B2.2.1.
The enclosure can be fl oor mounted to
a solid, fl at surface using the optional Floor
Mounting Kit Part Number 9-5004.
B3. Electrical
B3.1.
Main power circuit: The Ozone Generator
is supplied with a standard power cord. Plug
the cord into a standard 120V grounded,
grounding type receptacle only.
NOTE:
The circuit must be protected by a
ground-fault circuit interrupter (GFCI) installed
in accordance with electrical codes. (A
transformer is required for export power
requirements).
12.63
26.50
12.63
Figure 7: Wall Mount