DEL Clean Ozone Laundry Systems
Installation & Operations Manual
13
B5. Ozone External Trigger Line
B5.1.
Locate the pressure line inside the washer/
extractor
electrical
area.
See Figure 10 (left top)
B5.2.
Cut pressure line and install the tee provided.
See Figure 10 (left bottom)
B5.3.
Connect the 3/16”I.D. tubing from the tee to
the Ozone External Trigger Line port on the side
of the ozone generator.
B5.3.1.
Be sure the tubing is free of kinks and
will not come into contact with any moving
parts.
B6. Ozone gas destruct
B6.1.
Using a length of EPDM rubber hose, connect
the vent destruct to the 3” PVC vent port on the
back of the washer.
See Figure 11.
B6.1.1.
Secure the destruct to the vent with
hose
clamps.
B7. Installation Completion
B7.1.
Run a test cycle to check for leaks and ozone
functionality.
B7.1.1.
When the washer has fi lled, the ozone
light on the front of the ozonator unit should
illuminate green until the washer drains.
B7.1.2.
Refer to the troubleshooting section of the
manual for any problems.
Figure 10: Installing the Ozone Trigger Line
in the Pressure Line
Figure 11: Carbon Vent Destruct
Pressure
Transducer
Pressure
Line
Washer
Front Panel
Pressure
Line
Tee
EPDM
Rubber Hose
3" PVC
Vent
Ozone Vent