1
AGW–4015/4025/4045
Installation & Operations Manual
Water Quality:
Potable, mineral & chemical free
water
NOTE: Water passing through the AGW–4015
/4025/4045 cools the ozone generator module.
Ozone effectiveness, generator efficiency
and service life will be improved at water
temperatures of 60 - 80°F.
Overall Dimensions:
64”H x 32”W x 28”D
Shipping Weight w/Crate:
Approx. 500 pounds
Dry Weight:
Approx. 450 pounds
Ambient Temp.:
Operation: Ambient Temperature 40°F - 100°F
WARNING: Not to exceed 100°F or damage to
system may result!
SECTION 2
Installation
2A. Location
The AGW–4015/4025/4045 skid is designed to be
conveniently forklifted to a location close to your
process. This can be a level location indoors or
covered outdoors. Allow for access to electrical
power and required water connections.
SECTION 1
General Information
1A. Description
The AGW–4015/4025/4045 described in this
manual recirculates ozone-enriched water through
tanks sized from 50 gallons to 2,500 gallons. It is
designed to "charge" a given tank of water with
ozone for safe and effective clean in place (CIP)
and clean out of place (COP), direct contact on
food products, and general water sanitation/
disinfection.
1B. Specifications
4015
4025
4045
Ozone Output,
g/hr
15
25
45
Ozone Flow (max),
scfh
13
18
30
% Weight 0
3
4.2
4.2
4.2
Power Requirements:
230VAC, 60 Hz, 1Ø, 20A Service
• AGW–4015
• AGW–4025
• AGW–4045
480VAC, 60 Hz, 1Ø, 15A Service
• AGW–4015–480
• AGW–4025–480
• AGW–4045–480
230VAC, 50 Hz, 1Ø, 25A Service
• AGW–4015–50
• AGW–4025–50
• AGW–4045–50
Water Flow Rate:
35-40 GPM, factory set
NOTE: The purpose of the pump in the
AGW–4015/4025/4045 is to provide the proper
pressure and flow rate for the most efficient
injector operation. It is designed to circulate
cold water only. The inlet of the AGW–4015
/4025/4045 should never be connected directly
to a pressurized water source and the outlet
should never be throttled or restricted. Please
call DEL if further explanation is required.
Water Requirements:
Temperature:
40°F - 80°F
Pressure:
0 - 10 psi
Figure 1: AGW–4015/4025/4045
Skid-Mounted Ozone Sanitation System
Summary of Contents for AGW Series
Page 2: ......
Page 7: ...3 AGW 4015 4025 4045 Installation Operations Manual 3A Tank Charging System ...
Page 8: ...4 AGW 4015 4025 4045 Installation Operations Manual 3B Tank Cleaning System ...
Page 9: ...5 AGW 4015 4025 4045 Installation Operations Manual 3C Spray System ...
Page 15: ...11 AGW 4015 4025 4045 Installation Operations Manual 60 Hz Electrical Diagram ...
Page 16: ...12 AGW 4015 4025 4045 Installation Operations Manual 60 Hz Electrical Diagram cont ...
Page 17: ...13 AGW 4015 4025 4045 Installation Operations Manual 50 Hz Electrical Diagram ...
Page 18: ...14 AGW 4015 4025 4045 Installation Operations Manual 50 Hz Electrical Diagram cont ...
Page 25: ...21 AGW 4015 4025 4045 Installation Operations Manual APPENDIX A DAILY DATA LOG ...
Page 26: ...22 AGW 4015 4025 4045 Installation Operations Manual ...
Page 27: ...23 AGW 4015 4025 4045 Installation Operations Manual APPENDIX B EMERGENCY INFORMATION ...
Page 28: ...24 AGW 4015 4025 4045 Installation Operations Manual ...
Page 29: ...25 AGW 4015 4025 4045 Installation Operations Manual APPENDIX C SAFETY ...
Page 35: ......