Instruction manual for spiral mixer mod. CPM80-200
Lighting
Adequate lighting is necessary to carry out both normal operation and servicing of the
machine in a safe way. The machine has no built-in lighting system.
A well lit environment prevents hazards due to shadowed areas.
Acceptable environmental conditions for the installation site :
•
Temperature :
from 5
°
C to +40
°
C with the average temperature not exceeding
35°C over a period of 24 hours.
•
Relative humidity:
from 50% at a temperature of 40°C up to 90% at a
temperature of 20°C.
4.6
Preparation for start-up
Electrical connections
The machine has only one connection to the main electricity supply
Hydraulic connections
The machine ( model CPMel ) has only one hydraulic connection. The hose must have
a ½ “ fastening.
DANGER:
Be sure that the values of the main electricity supply comply with the
power specifications of the machine.
Electrical hazards. Be sure that the machine is adequately earthed before making any
other connection to the main power supply.
4.7
Testing
Before delivery the machine is tested at the manufacture’s workshop where the
following operations are carried out :
•
General setting of the machine, of auxiliary equipment and of the installed
safety devices.
•
Running test to check all adjustments have been carried out ( correct rotation
of the motors, tightness of the pneumatic systems, effectiveness of safety
devices and of limit switches ).
•
Performance of test cycles under safe conditions.