Page
25
of
32
For more information contact us: 970.493.1901 or
Document #7650-0005 Rev D1. © Copyright 2018 Directed Energy, Inc. All rights reserved.
TRIG:INT:MAIN:DUTYCYCLE nn.nn
Sets the duty cycle of the pulse in percent. The value of n.nn must have two
decimal places and be from 1.00 to 99.00. Example:
TRIG:INT:MAIN:DUTYCYCLE 28.10
TRIG:INT:MAIN:DUTYCYCLE 28.10
TRIG:SS:PULSEWIDTH?
Returns the Single Shot pulse width in nanoseconds. Example:
If the pulse width is 1100 ns then the response will be:
TRIG:SS:PULSEWIDTH?
1.100 µs
If the pulse width is 500001100 ns then the response will be:
TRIG:SS:PULSEWIDTH?
500.001100 ms
TRIG:SS:PULSEWIDTH n
Sets the Single Shot pulse width always in nanoseconds. The value of n must be
from 200 ns to 1,000,000,000 ns in 100 ns increments. Example:
TRIG:SS:PULSEWIDTH 180000000
TRIG:SS:PULSEWIDTH 180000000
Note:
To enable a single shot, send an OUTPUT:ENABLE command. The computer
must have a delay of 2000 ms before sending any other command to the system.
MAIN:CURRENT:SETPOINT?
Returns the Main Output Current in amperes. Example:
MAIN:CURRENT:SETPOINT?
1.100 Amps
MAIN:CURRENT:SETPOINT n
Sets the Main Output Current in mA. The value of n must be from 0 mA to 3100
mA. Example:
MAIN:CURRENT:SETPOINT 1100
MAIN:CURRENT:SETPOINT 1100
BIAS:CURRENT:SETPOINT?
Returns the Bias Output Current in amperes. Example:
BIAS:CURRENT:SETPOINT?
0.110 Amps