Operation
Setup
NOTE:
Any change to a command adjustment requires <200ms (typically) to
complete.
1. Make sure the PCX-7401 has been OFF for at least ten minutes.
2. Make sure the diode connection is in the correct polarity. If necessary review the
output cable for polarity specifications.
3. Make the other connections as necessary: External Trigger, External Bias, Sync,
Rear Enable, or the connection to the computer.
4. Connect the power cable.
Power Up
1. Turn on the power switch. The instrument powers up in about 3 seconds.
2. The instrument plays a tune and displays DEI information.
3. After a few seconds, the PCX-7401 displays the
Home
screen.
Keyswitch, Rear Enable, Output Connector, Internal Temperature
Output Current
Duty Cycle icon sets
the output duty cycle
Tools icon displays
the Settings menu
Frequency icon sets
the output frequency
Internal Trigger or
External Trigger icon
Bias Current