19
Attachments
1. Chart for setting the transmitter adress
adress 1
2
3
4
5
1
ON OFF OFF OFF OFF
2
OFF ON OFF OFF OFF
3
ON ON OFF OFF OFF
4
OFF OFF ON OFF OFF
5
ON OFF ON OFF OFF
6
OFF ON ON OFF OFF
7
ON ON ON OFF OFF
8
OFF OFF OFF ON OFF
9
ON OFF OFF ON OFF
10
OFF ON OFF ON OFF
11
ON ON OFF ON OFF
12
OFF OFF ON ON OFF
13
ON OFF ON ON OFF
14
OFF ON ON ON OFF
15
ON ON ON ON OFF
adress 1
2
3
4
5
16
OFF OFF OFF OFF ON
17
ON OFF OFF OFF ON
18
OFF ON OFF OFF ON
19
ON ON OFF OFF ON
20
OFF OFF ON OFF ON
21
ON OFF ON OFF ON
22
OFF ON ON OFF ON
23
ON ON ON OFF ON
24
OFF OFF OFF ON ON
25
ON OFF OFF ON ON
26
OFF ON OFF ON ON
27
ON ON OFF ON ON
28
OFF OFF ON ON ON
29
ON OFF ON ON ON
30
OFF ON ON ON ON
31
ON ON ON ON ON
2. Table of error codes
code
cause
solution
1
Sensor is not present
(EEPROM is not
communicating)
Disconnect and
reconnect the sensor,
then restart the sensor
by disconnecting and
reconnecting the power
2
Unknows sensor type
Contact the
manufacturer
3
Type 2 senesor type ID
not found in the table
setting LMP91000
Contact the
manufacturer - FW
update required
4
CRC does not match the
sensor EEPROM
Sensor error - contact
the manufacturer
5
LMP91000 does not
respond
Sensor error - contact
the manufacturer
6
The set sensor ID does
not match with the
connected sensor
Checking the
configuration of the
sensor required
7
Reserved
Reserved
8
EL sensor test error
Sensor error
9
Transmitter is in
preheating mode
Wait a few minutes, the
transmitter will
automatically enter
measurement mode
10
Reserved
11
reserved
12
Error reading the internal
FLASH
Restart the transmitter.
If the error persists,