Draw a fine vertical line on the wall from 
the rear-centre of the hob to the ceiling. 

• 

Draw another line, horizontal this time, 
where the bottom edge of the hood 
should be. 

(A minimum distance be-

tween the hob and the hood of 750mm 
is recommended.)  

• 

Take the template card and separate the 
ceiling mounting template from the hood 
mounting template by cutting along the 
indicated line. 

• 

Using masking tape, stick the ceiling 
mounting template to the wall directly 
below the ceiling and centered on the 
vertical  line. 

  Installation.. 

Installation sequence; 

1. 

Extractor unit / chimney brackets. 

2. Top 

chimney 

duct 

3. 

Bottom chimney duct 

 

• 

Carefully remove the extractor hood and 
the components from the packaging. 

• 

Remove the grease filters.

 

• 

In a similar fashion stick the hood mount-
ing template on the wall ensuring that the 
centre-lines line up with those drawn on 
the wall. 

• 

Note that the holes marked on the tem-
plate cater for both 600mm and 900mm 
wide models. Please ensure that you only 
use those markings relating to the model 
you have purchased. 

Holes for Triangular 600 are marked 
with a (1).  
Holes for Triangular 900 are marked 
with a (2). 
Holes not marked are common to all 
models.  

• 

For mounting the chimney brackets, drill 
6 holes, 5mm in diameter and 45mm deep 
into the wall as indicated on the mounting 
template. 

• 

For mounting the extractor hood, drill 4 
holes, 8mm in diameter and 60mm deep 
as indicated on the mounting template. 

• 

Once all the holes have been drilled the 
templates must be removed. 

• 

Push the 5mm Dia. wall plugs through the 
holes in the chimney mounting brackets. 
Insert the plugs into the drilled holes to-
gether with the chimney mounting bracket 
and fasten securely. 

• 

Push the 8mm Dia. wall plugs into the 
8mm Dia. holes ensuring that they are 
flush with the wall. 

• 

Partially screw two 6mm Dia. screws into 
the two top wall plugs leaving them to 
protrude about 10mm. 

• 

Lift and hook the extractor hood over and 
onto the two protruding screws through 
the key-hole slots provided at the top of 
the extractor hood frame. 

• 

Insert the other two 6mm Dia. screws 
through the holes inside the extractor 
hood housing and into the 8mm Dia wall 
plugs. 

• 

Align the extractor hood with the centre 
and horizontal lines before tightening all 
four 6mm screws. 

CUT TEMPLATE

TOP OF CEILING

LINE FROM CENTRE 
OF STOVE TO CEILING

750

CEILING MOUNTING TEMPLATE

HOOD TEMPLATE

HORIZONTAL 
LINE

CEILING MOUNTING 
BRACKET POSITION

Summary of Contents for DCH260

Page 1: ... improvements For this reason the text and illustrations in this book are subject to change without notice Part Number 066044 INDEX 2 Description 2 Before use 2 Safety advice 2 Electrical connection 3 Preparing for installation 3 Recirculating filtered air 3 Venting air to the outside 4 Installation 6 Grease filters 6 Optional carbon pad filters 7 Operation 7 Replacing the light bulbs 8 Maintenanc...

Page 2: ...nd the chimney area A qualified electrician should provide this facility The extractor hood must be earthed The manufacturer and the seller do not accept responsibility for any dam age due to incorrect electrical connec tion This extractor hood may not be used with a battery inverter power supply Before use This extractor hood complies with all relevant safety regulations The extractor hood is not...

Page 3: ... burning gas or fuels Please ensure that regulations concern ing the discharge of exhaust air have been fulfilled SABS IEC 60335 2 31 For optimum extractor hood efficiency use a short smooth round air exhaust pipe with as few bends as possible A 150mm diameter exhaust pipe is recommended Long box section narrowed or bent pipes will hinder performance and increase noise levels Connecting a 150 mm d...

Page 4: ...iangular 900 are marked with a 2 Holes not marked are common to all models For mounting the chimney brackets drill 6 holes 5mm in diameter and 45mm deep into the wall as indicated on the mounting template For mounting the extractor hood drill 4 holes 8mm in diameter and 60mm deep as indicated on the mounting template Once all the holes have been drilled the templates must be removed Push the 5mm D...

Page 5: ...ve film from the chimney ducting taking care not to dam age the polished stainless steel surface Fit the upper chimney duct section the one with louvre outlets to the ceiling mounting bracket using the screws sup plied INSERT 6 SELF TAPPING SCREWS Fit the lower chimney duct to the lower wall mounting bracketand tighten the six screws on the inside of the extractor hood Drill 3 5mm Dia holes throug...

Page 6: ...and release the catch To remove the filter for cleaning pur poses reverse the procedure described above Grease filters Carbon pad filters assist in removing any unwanted cooking odours from the at mosphere If your installation ducts filtered air to the outside the carbon pad filters are not re quired Should you require them factory ap proved carbon pad filters and installation kits may be purchase...

Page 7: ... equivalent bulb Fit the glass cover and replace the re taining ring Switch on the electricity supply Select the fan speed you require Push button 3 for high extraction level Push button 2 for medium Push button 1 for low The fan indicator light will glow when the fan is operating To switch the fan off push the motor speed OFF button 0 If required you may illuminate the cooking area by switching t...

Page 8: ...ree soft cloth or synthetic sponge Soap or mild liquid detergent A mild window cleaner Diluted ammonia in warm water A nylon bristle brush Cleaners labelled Suitable for stainless steel Do not use A steam cleaner Acid alcohol soda chloride or spirit based cleaners Coarse abrasive cleaning powders Metallic scourers steel wool metal scrapers or plastic scouring pads Wire brushes or emery paper So ca...

Page 9: ...e agents Consult the nearest regional service centre for details BLOEMFONTEIN 160 Long Street Hilton Bloemfontein 9301 Tel 051 400 3900 Bloemfontein Service defy co za CAPE TOWN 5A Marconi Rd Montague Gardens 7441 Tel 021 551 8314 CapeTown Service defy co za DURBAN 35 Intersite Avenue Umgeni Business Park Durban 4051 Tel 031 268 3300 Durban Service defy co za EAST LONDON 16 Bowls Rd Arcadia East L...

Page 10: ...ition of these warranties that the purchaser takes due care and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating in structions connection to incorrect voltages and subjection to commercial use shall release the Company from its obligations 3 This warranty shall become void and cease to operate if the appliance is dismantled by or any re pairs to the app...

Reviews: