Never operate the extractor hood without 
a grease filter. 

• 

Never leave cooking fat or oil unat-
tended. Overheated fat or oil can easily 
catch fire.   

• 

Do not flambé food directly under the ex-
tractor hood. The flames pose the risk of 
the grease filter catching fire.( see page 8 
Maintenance and cleaning) 

• 

Restrictions apply to the use of the ex-
tractor hood over a solid fuel or gas 
stove. (See Preparing for installation on 
page 3). 

• 

Switch off the power at the mains in the 
event of a fault or when cleaning the ex-
tractor hood

 

• 

Do not touch any part of the light fittings 
while they are in use as they get very hot 
and could cause severe burns.

 

  Electrical connection. 

  Safety advice. 

• 

The extractor hood uses a 220-
250V/50Hz power supply. 

• 

If the mains power cord is damaged, it 
must be replaced by a qualified electri-
cian.  

• 

The power cord is located in the chimney 
area. Should you require an installation 
with no visible wiring, a 15 amp earthed 
plug socket should be accessible  either in 
the ceiling above the extractor hood or on 
the wall behind the chimney area. 

 

 

 

 

 

 

 

 

 

(A qualified electrician should provide 
this facility).

 

• 

The extractor hood must be earthed. 
The manufacturer and  the seller do 
not accept responsibility for any dam-
age due to incorrect electrical connec-
tion.

 

• 

This extractor hood may not be used 
with a battery inverter power supply.

 

  Before use. 

• 

This extractor hood complies with all 
relevant safety regulations.

 

• 

The extractor hood is not intended for use 
by young children or infirm persons with-
out supervision.  

 

Before using your new extractor hood  for 
the first time, please read this manual care-
fully. It contains important information con-
cerning your personal safety as well as on 
the use and care of the extractor hood. 

• 

Remove all packaging (except the protec-
tive film on the two chimney sections) 
and dispose of it in an environmentally 
friendly manner.  

• 

 If the extractor hood is damaged in any 
way, do not use it. Report the damage to 
your dealer, who will take the necessary 
corrective action. (Refer to Owner’s re-
sponsibility on page 9 of this manual).  

  Description. 

• 

The extractor hood fan extracts the 
kitchen vapours and passes them through 
the grease filter. 

• 

The grease filter absorbs the solid parti-
cles in the cooking vapours, keeping the 
kitchen almost free of grease. 

Summary of Contents for DCH260

Page 1: ... improvements For this reason the text and illustrations in this book are subject to change without notice Part Number 066044 INDEX 2 Description 2 Before use 2 Safety advice 2 Electrical connection 3 Preparing for installation 3 Recirculating filtered air 3 Venting air to the outside 4 Installation 6 Grease filters 6 Optional carbon pad filters 7 Operation 7 Replacing the light bulbs 8 Maintenanc...

Page 2: ...nd the chimney area A qualified electrician should provide this facility The extractor hood must be earthed The manufacturer and the seller do not accept responsibility for any dam age due to incorrect electrical connec tion This extractor hood may not be used with a battery inverter power supply Before use This extractor hood complies with all relevant safety regulations The extractor hood is not...

Page 3: ... burning gas or fuels Please ensure that regulations concern ing the discharge of exhaust air have been fulfilled SABS IEC 60335 2 31 For optimum extractor hood efficiency use a short smooth round air exhaust pipe with as few bends as possible A 150mm diameter exhaust pipe is recommended Long box section narrowed or bent pipes will hinder performance and increase noise levels Connecting a 150 mm d...

Page 4: ...iangular 900 are marked with a 2 Holes not marked are common to all models For mounting the chimney brackets drill 6 holes 5mm in diameter and 45mm deep into the wall as indicated on the mounting template For mounting the extractor hood drill 4 holes 8mm in diameter and 60mm deep as indicated on the mounting template Once all the holes have been drilled the templates must be removed Push the 5mm D...

Page 5: ...ve film from the chimney ducting taking care not to dam age the polished stainless steel surface Fit the upper chimney duct section the one with louvre outlets to the ceiling mounting bracket using the screws sup plied INSERT 6 SELF TAPPING SCREWS Fit the lower chimney duct to the lower wall mounting bracketand tighten the six screws on the inside of the extractor hood Drill 3 5mm Dia holes throug...

Page 6: ...and release the catch To remove the filter for cleaning pur poses reverse the procedure described above Grease filters Carbon pad filters assist in removing any unwanted cooking odours from the at mosphere If your installation ducts filtered air to the outside the carbon pad filters are not re quired Should you require them factory ap proved carbon pad filters and installation kits may be purchase...

Page 7: ... equivalent bulb Fit the glass cover and replace the re taining ring Switch on the electricity supply Select the fan speed you require Push button 3 for high extraction level Push button 2 for medium Push button 1 for low The fan indicator light will glow when the fan is operating To switch the fan off push the motor speed OFF button 0 If required you may illuminate the cooking area by switching t...

Page 8: ...ree soft cloth or synthetic sponge Soap or mild liquid detergent A mild window cleaner Diluted ammonia in warm water A nylon bristle brush Cleaners labelled Suitable for stainless steel Do not use A steam cleaner Acid alcohol soda chloride or spirit based cleaners Coarse abrasive cleaning powders Metallic scourers steel wool metal scrapers or plastic scouring pads Wire brushes or emery paper So ca...

Page 9: ...e agents Consult the nearest regional service centre for details BLOEMFONTEIN 160 Long Street Hilton Bloemfontein 9301 Tel 051 400 3900 Bloemfontein Service defy co za CAPE TOWN 5A Marconi Rd Montague Gardens 7441 Tel 021 551 8314 CapeTown Service defy co za DURBAN 35 Intersite Avenue Umgeni Business Park Durban 4051 Tel 031 268 3300 Durban Service defy co za EAST LONDON 16 Bowls Rd Arcadia East L...

Page 10: ...ition of these warranties that the purchaser takes due care and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating in structions connection to incorrect voltages and subjection to commercial use shall release the Company from its obligations 3 This warranty shall become void and cease to operate if the appliance is dismantled by or any re pairs to the app...

Reviews: