![DEEP SEA ELECTRONICS DSECONTROL DSE7000 Series Operator'S Manual Download Page 11](http://html.mh-extra.com/html/deep-sea-electronics/dsecontrol-dse7000-series/dsecontrol-dse7000-series_operators-manual_2463069011.webp)
DSE Model 7000 Series Control & Instrumentation System Operators Manual
Part No. 057-074 7000 Series OPERATING MANUAL ISSUE 2 02/05/2008 ADM
11
3.5.3 CHARGE FAIL INPUT
Minimum voltage
0V
Maximum voltage
35V (plant supply)
Resolution
0.2V
Accuracy
± 1% of max measured voltage
Excitation
Active circuit constant power output
Output Power
2.5W Nominal @12V and 24V
Current at 12V
210mA
Current at 24V
10mA
3.5.4 MAGNETIC PICKUP
Type
Differential input
Minimum voltage
0.5V RMS
Max common mode
voltage
±2V
Maximum voltage
Clamped to ±70V by transient suppressers, dissipation not to exceed 1W.
Maximum frequency
10,000Hz
Resolution
6.25 RPM
Accuracy
±25 RPM
Flywheel teeth
10 to 500
3.6 OUTPUTS
3.6.1 OUTPUTS A & B
Type
Normally used for Fuel / Start outputs. Fully configurable for other purposes if the
module is configured to control an electronic engine. Supplied from Emergency Stop
terminal 3.
Rating
15A @ 35V
3.6.2 OUTPUTS C & D
Type
Voltage free relays, fully configurable, normally used for generator / mains load switch
control.
Rating
8A @ 250 V AC
3.6.3 OUTPUTS E,F,G & H
Type
Fully configurable, supplied from DC supply terminal 2.
Rating
3A @ 35V