Select the Mounting Place
Both RF-360s detect a direction in
alignment to the right. The over-
lapping area covers the complete
bearing of the other RF-360. The
position can’t be determind.
Both RF-360s detect a direction
against each other. No exact position
can be determined.
With three RF-360s there is no blind
area. The third RF-360s can always
varify the area of intersection.
?
?
Distances between the RF-360s
The distance between the RF-360 usually should be 330 ft to 1,300 ft (100 m to 400 m).
`
For the best result, Dedrone strongly recommends a distance of
1,000 ft to 1,300 ft (300 m to
400 m)
.
`
Choose the postion depending on your monitoring focus. Increase the distance between the
sensors to increase the accuracy at further distances.
`
Localization accuracy increases as the drone gets closer to the sensors.
5.3 Mounting Location
Mounting Surface
•
Make sure the selected mounting surface is capable of supporting the combined weight of the
RF-360 (12.2 lb (5.5 kg)) and the pole under all expected conditions of load, vibration, and tem-
perature.
330 ft to 1,300 ft
(100 m to 400 m)
330 ft to 1,300 ft
(100 m to 400 m)
330 ft to 1,300 ft
(100 m to 400 m)
Distance between the RF-360s