8 Troubleshooting
8.1 Messages (Ex and Px type code)
Fig.26 Faults display
8.1.1 Messages on the display
Set Temp
Timer 1
On Off
Timer 2
On Off
Set Temp
Error
Electrical
Heating
Heating
NIE-A-094
Electrical
Heating
Enter
Timer /
Clock
Error
In the event of disruption, the control panel displays a message and
a corresponding code:
- The "spanner" pictogram appears
- The green warning light flashes
1
Make a note of the code displayed.
The code is important for the correct and rapid diagnosis of the type of
error and for any technical assistance that may be needed.
2
Switch off and then switch the appliance back on.
The appliance starts up again autonomously when the reason for the
disruption has been cleared.
3
If the code is displayed again, correct the problem by following the
instructions in the table below:
Code Description
Check / Solution
E2
Communication error between the outdoor unit and
the display
Contact the professional who handles maintenance of the
appliance
E4
T5L water temperature sensor error
Contact the professional who handles maintenance of the
E5
T3 evaporation temperature sensor error
Contact the professional who handles maintenance of the
E6
T4 air temperature sensor error
Contact the professional who handles maintenance of the
E9
Th suction temperature sensor error
Contact the professional who handles maintenance of the
EA
Tp discharge temperature sensor error
Contact the professional who handles maintenance of the
EP
Electrical differential error
Contact the professional who handles maintenance of the
P1
High pressure error
Contact the professional who handles maintenance of the
P2
Electrical overconsumption error on the
compressor
Contact the professional who handles maintenance of the
appliance
P4
Discharge temperature error: too high
Contact the professional who handles maintenance of the
bA
Air temperature information outside the operating
limits
The weather and/or installation conditions do not enable the heat
pump to operate. Hot water is produced by the electrical back-up.
EF
Error on the main controller
Contact the professional who handles maintenance of the
appliance
db
Frost protection running
Contact the professional who handles maintenance of the
appliance
Note
Press the Down Arrow key and Enter simultaneously for 3
seconds to clear the errors.