23
7638216-02 - 19062015
KALIKO SPLIT
Fig.16 Starting the heating process
5.1.3 Setting the operating ranges
Timer 1
On
Off
Timer 2
On Off
Set Temp
Error
Electrical
Heating
Heating
NIE-A-068
Enter
Electrical
Heating
Timer /
Clock
Two operating ranges are available: Timer 1 and Timer 2.
Both operating ranges are set in a similar manner.
For each operating range, set a start time and an end time.
1
Press
Timer/Clock
three times to select Timer 1 - On.
2
The display “hh” on the “hh : mm” display starts flashing, meaning that
the start time for the heating process is ready to be set.
Fig.17 Setting the start time
Timer 1
On
Off
Timer 2
On Off
Set Temp
Error
Electrical
Heating
Heating
NIE-A-079
Enter
Electrical
Heating
Timer /
Clock
3
Press the
up/down arrows
to go forwards or back.
Fig.18 Minutes setting
Timer 1
On
Off
Timer 2
On Off
Set Temp
Error
Electrical
Heating
Heating
NIE-A-080
Enter
Electrical
Heating
Timer /
Clock
4
Press
Timer/Clock
5
The minutes display starts flashing.
6
Set the minutes using the
up/down arrows
to go forwards or back.
Fig.19 Confirmation
Timer 1
On
Off
Timer 2
On Off
Set Temp
Error
Electrical
Heating
Heating
NIE-A-081
Electrical
Heating
Enter
Timer /
Clock
7
Press
Timer/Clock
to confirm.
The start time of the heating process is confirmed.
5 Using the appliance