15
7638216-02 - 19062015
KALIKO SPLIT
3.2 Technical data
3.2.1 Characteristics of the appliance
Model
Unit
TWH Split FS 200 E TWH Split FS 270 E
Daily electricity consumption (
Q
elec
)
kWh
3.532
5.576
Declared load profile
L
XL
Sound power level at 1 m indoors (
L
WA
)
(4)
dB(A)
<17
<17
Daily fuel consumption (
Q
fuel
)
kWh
0
0
Emissions of nitrogen oxides (
NO
X
)
mg/kWh
0
0
Weekly fuel consumption with smart controls (
Q
fuel, week,smart
)
kWh
-
-
Weekly electricity consumption with smart controls (
Q
elec, week,smart
)
kWh
-
-
Weekly fuel consumption without smart controls (
Q
fuel, week,smart
)
kWh
-
-
Weekly electricity consumption without smart controls (
Q
elec, week,smart
)
kWh
-
-
Storage volume (V)
I
215
270
Mixed water at 40°C (V40)
I
299
373
Sound power level, outdoors (
L
WA
)
(4)
dB(A)
59
59
Output (outdoor unit) air temperature = 7°C
W
1750
1750
Absorbed electrical power (outdoor unit)
W
900
900
Heating time (10-54°C)
(1)
hours
5.5
7.1
COP in accordance with the EN16147 standard
(1)
3.30
3.42
Pes (Output)
(1)
(3)
W
26.5
28.5
Air flow rate – maximum
m
3
/h
1300
1300
Electrical resistor output
W
2400
2400
Operating pressure
MPa (bar)
1.0 (10)
1.0 (10)
Power supply voltage
V
230
230
Circuit breaker
A
16
16
Refrigerant fluid R134a
kg
1.60
1.60
Length of the refrigeration connection (minimum / maximum)
m
2 / 20
2 / 20
Maximum difference in height on the refrigeration connection
m
10
10
Weight of the domestic hot water tank (empty)
kg
70
82
Protection of the domestic hot water tank
IP
X1B
X1B
Weight of the outdoor unit
kg
33
33
Protection of the outdoor unit
IP
24
24
Limit operating temperatures of the outdoor unit
°C
-15 / 42
-15 / 42
Settings range for the domestic hot water set point
°C
38/75
38/75
(1) Value obtained with an air temperature of 7°C and a water temperature of 10°C, according to LCIE Specifications No. 103-
15/B:2011 based on the NF EN 16147 standard, with a 5-m long refrigeration connection with 0 m difference in height.
(2) Equivalent hot water volume at 40°C.
(3) Electrical power consumed with no hot water use.
(4) Value obtained at 20°C air on average during heating from 10°C to 55°C.