3 Technical specifications
3.1
Certifications
3.1.1.
Electrical compliance / Marking CE
This product complies to the requirements to the european directives
and following standards:
4
2006/95/EC Low Voltage Directive
Reference Standard: EN 60.335.1.
4
2004/108/EC Electromagnetic Compatibility Directive
Reference Standard: EN 50.081.1 / EN 50.082.1 / EN 55.014.
3.2
Technical specifications
3.2.1.
Characteristics of the appliance
Model
TWH 300 E
TWH 300 EH
TWH 200 E
Capacity
litres
270
260
215
Weight (empty)
kg
105
123
92
R134a refrigerant
kg
1.45
1.45
1.45
Output (HP) -Air temperature = 15°C
W
1700
1700
1700
Electrical resistor output
W
2400
2400
2400
Operating pressure
bar (MPa)
10 (1,0)
10 (1,0)
10 (1,0)
Power supply voltage
V
230
230
230
Circuit breaker
A
16
16
16
Ambient air performance
Absorbed electrical power (HP)
W
470
470
460
COP
(1)
-
2.44
2.64
2.55
COP
(2)
-
3.31
3.26
3.17
Vmax
(3)
litres
385
380
289
Pes
(2)(4)
W
42
41
33
Outside air performance
Absorbed electrical power (HP)
W
500
500
500
COP
(1)
-
2.94
2.75
2.9
(1) Value obtained with an air temperature of 7 and a water inlet at 10 °C, as per EN16147 based on Specification LCIE N°103-15/B:2011
(2) Value obtained with an air temperature of 15 and a water inlet at 10 °C, as per EN16147 based on Specification LCIE N°103-15/B:2011
(3) Maximum volume of hot water that can be used at a temperature of 40°C
(4) Power consumption in stabilised regime
(5) The installation of suction and backflow conduits on the heat pump lessens its performance
(6) Domestic cold water input at 10°C - Primary inlet temperature at 80°C
(7) Output: 34.1 kW
3. Technical specifications
TWH 200E TWH 300E TWH 300EH
13
01/12/2015 - 7605313-001-07