Parameters Description
Adjustment
range
Factory
setting
P 01
DHW setpoint in
Auto
mode
40 to 70 °C
55 °C
P 02
DHW set point in
Eco
mode
40 to 65 °C
55 °C
P 04
Choice of mode for the DHW Comfort period:
4
0 = Use the time programs.
4
1 = Use the electricity tariff information input. Tells you whether or not domestic
hot water production is permitted (HP1 = not permitted => Contact closed, HC0
= permitted => Contact open).
4
2 = Use the electricity tariff information input. Tells you whether or not domestic
hot water production is permitted (HP1 = not permitted => Contact open, HC0
= permitted => Contact closed).
4
3 = Use the time programs. The status of the electricity tariff information input
is used to activate the Boost function with compressor only (HP1 = Boost
deactivated => Contact closed, HC0 = Boost activated => Contact open).
4
4 = The status of the electricity tariff information input is used to activate the
Boost function with compressor only (HP1 = Boost activated => Contact open,
HC0 = Boost deactivated => Contact closed).
4
5 = The status of the electricity tariff information input is used to activate the
Boost function with compressor and back-up (HP1 = Boost deactivated =>
Contact closed, HC0 = Boost activated => Contact open).
4
6 = The status of the electricity tariff information input is used to activate the
Boost function with compressor and back-up (HP1 = Boost activated =>
Contact open, HC0 = Boost deactivated => Contact closed).
0 - 6
0
P 06
Automatic switch to summer time (last Sunday in March) and winter time (last
Sunday in October):
4
0 = Function not active (for countries where the time change is done on other
dates or is not in use)
4
1 = Function activated
0 - 1
1
P 07
DHW setpoint in
Boost
mode
40 to 70 °C
62 °C
5.3.6.
Return to the factory settings
1. Press the
(
and
)
keys
simultaneously
for 5 seconds. The
rSt
menu is displayed.
2. Press the
MODE
B
key to carry out a TOTAL RESET of all
parameters.
C003495-C
3
1
4
3
4
1
2
MENU
MODE
C004193-A
1
4
3
4
1
2
MENU
MODE
5. Operating the appliance
TWH 200E TWH 300E TWH 300EH
25