6.2
Error memory
The boiler control is equipped with an error memory. The last 16 errors
encountered are recorded in this memory.
In addition to the error codes, the following data are also saved:
4
Number of times that the error occured: (
MK[xx
).
4
Boiler operating mode selected (
5t[xx
).
4
The flow temperature (
t1[xx
) and the return temperature
(
t2[xx
) when the error occured.
To view the error memory, you first have to enter access code
0012
.
6.2.1.
Error readout memorised
1. Press the two keys
f
simultaneously and then key
[+]
until the
symbol
a
flashes on the menu bar.
2. Select the installers menu using the key
S
.
c0de
appears
on the display.
3. Use keys
[-]
or
[+]
to input the installer code
0012
.
4. Press the
S
key.
er[xx
appears on the display.
5. The fault list or shutdown list can be displayed by pressing the
[-]
or
[+]
key.
6. Confirm using key
S
.
er[xx
is displayed with
xx
flashing = Last error which occured, For example
K2
.
7. Use the
[-]
or
[+]
key to scroll through the faults or shutdowns.
8. Press the
S
key to display the details of the faults or shutdowns.
9. Press the
j
key to interrupt the display cycle.
er[xx
is
displayed with
xx
flashing = Last error which occured.
10.Press the
j
key to show the fault list or shutdown list.
11.Press 2 times on the key
j
to exit the error memory.