Parameters
Description
Factory setting
Customer setting
COLD
COOLING mode is forced without taking into account the
outside temperature or the SUM/WIN parameter.
MANUEL
The appliance operates according to the set point settings.
All of the pumps operate.
Possibility of setting the set point by simply turning the but
ton.
Domestic Hot Water menu - User Level
Tab.16 Domestic Hot Water menu (
)
Parameters
Description
Factory setting
AUTOMATIC
Domestic hot water production is determined by the setting in the #TIME
PROGRAM menu.
COMFORT 7/7
Domestic hot water production is forced at all times: seven days a week.
Current time + 1
hour
COMFORT ->
Domestic hot water production is forced until the set time:
Current time + 1
hour
#MEASURES menu - User Level
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.17 #MEASURES menu - User Level
Parameters
Description
Unit
OUTSIDE TEMP.
Outside temperature
°C
ROOMTEMP.A
Room temperature on circuit A
°C
ROOMTEMP.B
Room temperature on circuit B
°C
ROOMTEMP.C
Room temperature on circuit C
°C
HP FLOW TEMP.
Condenser flow temperature
°C
BACK TEMP HP
Condenser return temperature
°C
SOURCE T.IN
Intake temperature from the source
°C
SOURCE T.OUT
Flow temperature from the source
°C
PRESSURE
Water pressure in the system
bar
DHW TEMP.
Water temperature in the domestic hot water tank (top sensor)
°C
S.TAN.T.SYS.BO
Sensor temperature in the bottom of the storage tank
°C
STO.TANK.T.AUX
Sensor temperature in the top of the storage tank
°C
TEMPERATURE DCW
Temperature in the domestic hot water tank (bottom sensor)
°C
SWIMMING P.T.B
Water temperature of the swimming pool on circuit B
°C
SWIMMING P.T.C
Water temperature of the swimming pool on circuit C
°C
OUTLET TEMP.B
Water flow temperature in circuit B
°C
OUTLET TEMP.C
Water flow temperature in circuit C
°C
TEMP.SYSTEM
Water flow temperature in the system in the event of multiple sources
°C
TEMP.TANK AUX
Water temperature in the second domestic hot water tank connected to the Aux
iliary circuit
°C
6 Settings
30