6 Settings
6.1
List of parameters
6.1.1
User Level
Menus available at User level:
Access keys
Menus
TEMPERATURE
MODE
Operating mode
Domestic hot water
#MEASURES
#CHOICE TIME PROG.
#TIME PROGRAM
#SETTING
#TIME .DAY
TEMPERATURE menu - User Level
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.14 TEMPERATURE menu (
)
Parameters
Description
Factory setting
Customer setting
DAY TEMP.A
Desired room temperature in DAY mode on circuit A.
Can be set from 5 to 30°C.
20°C
NIGHT TEMP.A
Desired room temperature in NIGHT mode on circuit A.
Can be set from 5 to 30°C.
16°C
DAY TEMP.B
Desired room temperature in DAY mode on circuit B.
Can be set from 5 to 30°C.
20°C
NIGHT TEMP.B
Desired room temperature in NIGHT mode on circuit B.
Can be set from 5 to 30°C.
16°C
DAY TEMP.C
Desired room temperature in DAY mode on circuit C.
Can be set from 5 to 30°C.
20°C
NIGHT TEMP.C
Desired room temperature in NIGHT mode on circuit C.
Can be set from 5 to 30°C.
16°C
WATER TEMP.
Desired domestic hot water temperature in the domestic hot
water circuit.
Can be set from 40 to 75°C.
55°C
DHW A TEMP.
Desired temperature for the domestic hot water in a second
domestic hot water tank connected to circuit A.
Can be set from 10 to 80°C.
55°C
DHW B TEMP.
Desired temperature for the domestic hot water in a second
domestic hot water tank connected to circuit B.
Can be set from 10 to 80°C.
55°C
DHW TEMP.C
Desired temperature for the domestic hot water in a second
domestic hot water tank connected to circuit C.
Can be set from 10 to 80°C.
55°C
TEMP.TANK AUX
Desired temperature for the domestic hot water in a second
domestic hot water tank connected to the auxiliary circuit.
Can be set from 10 to 80°C.
55°C
6 Settings
28
GSHP