3.1.3
Regulations for commissioning installations for France
F30 biofuel is available in France from 01/07/2022.
Decree No. 2022-8 of 5 January 2022 of the Ministry for Energy Transition currently in force relating to F30 biofuel stipulates
that:
It is prohibited to install equipment which uses fuels emitting over 300 g CO
2
eq/kWh LHV based on life cycle assessment.
New boilers running on biofuels shall be permitted, provided that this threshold is respected.
Repair work on existing boilers shall still be possible.
3.2
Technical data
Tab.5
Technical parameters for boiler space heaters
Product name
CFU 36
F30
CFU 46
F30
Condensing boiler
No
No
Yes
Yes
B1 boiler
No
No
Cogeneration space heater
No
No
Combination heater
No
No
Rated heat output
Prated
kW
37
46
Useful heat output at rated heat output and high temperature regime
P
4
kW
37.2
46.4
Useful heat output at 30% of rated heat output and low temperature re
P
1
kW
11.6
14.5
Seasonal space heating energy efficiency
ƞ
s
%
86
86
Useful efficiency at rated heat output and high temperature regime
ƞ
4
%
87.3
86.9
Useful efficiency at 30% of rated heat output and low temperature re
ƞ
1
%
90.9
90.7
Auxiliary electricity consumption
Full load
elmax
kW
0.156
0.160
Part load
elmin
kW
0.064
0.066
Stand-by
P
SB
kW
0.004
0.004
Other specifications
Standby heat loss
P
stby
kW
0.109
0.122
Ignition burner power consumption
P
ign
kW
--
--
Annual energy consumption
Q
HE
GJ
124
154
Sound power level, indoors
L
WA
dB
63
65
Emissions of nitrogen oxides
NO
x
mg/kWh
118
118
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature
(at heater inlet).
(2) High temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
See
The back cover for contact details.
Tab.6
Burner specifications
Unit
CFU 36 F30 CFU 46 F30
Burner type
F10N3–1.40 F10N3–1.50
Oil flow rate
kg/h
3.4
4.2
F30 flow rate
kg/h
3.5
4.4
3 Technical specifications
10
CFU
7740570 - v04 - 03112022