30
EN
16 / INDICATIONS FOR THE TESTING LABORATORIES
ENERGY EFFICIENCY TESTS ACCORDING TO AS/NZS 2007 PROGRAMME : Normal Eco
— Washing capacity - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
14 standard place settings
— Arrangement of the items - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Figs. A-B-C ; see next page
— Loading as per the indications on the next page :
- with 2 shelves ( for 3 cups ),
- with 5 cup / saucer supports ( 4 for 12 s 1 dessert plate and 1 for 2 cups )
- with supports stemmed glass
- without cutlery drawers ( see page 17 ).
— Setting for upper basket - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Low position
— Dosage of detergent - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
5 + 27,5 g of detergent
— Setting for rinsing product distributor - - - - - - - - - - - - - - - - - -
3
— The water softener must be set to 0-1mmol/l
instructions in the paragraph on ““5 / WATER SOFTENER ADJUSTMENTS””.
— Door ajar 100 mm upon completion of dry test.
For more information on the comparison tests in accordance with AS/NZS 2007, please contact the
manufacturer of the machine before commencing testing.
NB: When conducting tests using a multi-function tablet :
— Check that the water softener is correctly set for the water hardness
(paragraph ““5 / WATER SOFTENER ADJUSTMENTS””)
- Pull out the detergent distribution drawer and place the tablet in the interior compartment.
45