Product name
AWHP 4MR–
EMC 24/28 MI
HYBRIDE
AWHP 6MR–
EMC 24/28 MI
HYBRIDE
AWHP 8MR–
EMC 24/28 MI
HYBRIDE
T
j
= operation limit temperature
Pdh
kW
2.8
3.6
5.6
Bivalent temperature
T
biv
°C
2
2
2
Degradation co-efficient
(2)
Cdh
—
1.0
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
150
133
135
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
132
122
125
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
195
166
169
Declared coefficient of performance or primary
energy ratio for part load at indoor temperature
20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
-
or
%
1.82
1.86
1.95
T
j
= +2 °C
COPd
-
or
%
3.88
3.40
3.49
T
j
= +7 °C
COPd
-
or
%
5.65
4.52
4.57
T
j
= +12 °C
COPd
-
or
%
9.33
6.70
6.33
T
j
= bivalent temperature
COPd
-
or
%
3.88
3.40
3.49
T
j
= operation limit temperature
COPd
-
or
%
1.47
1.52
1.63
Operation limit temperature for air-to-water
heat pumps
TOL
°C
-10
-10
-10
Heating water operating limit temperature
WTOL
°C
80
80
80
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
0.049
Stand-by
P
SB
kW
0.013
0.013
0.013
Crankcase heater mode
P
CK
kW
0.055
0.055
0.055
Supplementary heater
Rated heat output
(1)
Psup
kW
3.7
4.8
5.8
Type of energy input
Gas
Gas
Gas
Other characteristics
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
42 – 62
42 – 64
42 – 65
Annual energy consumption under average
conditions
Q
HE
kWh
GJ
2900
5
4312
7
5859
8
Annual energy consumption under colder con
ditions
Q
HE
kWh
GJ
3230
3
4236
3
6548
5
Annual energy consumption under warmer
conditions
Q
HE
kWh
GJ
887
0
1544
0
1904
0
3 Technical specifications
18