Tab.9
Technical parameters for heat pump space heaters (parameters declared for medium-temperature application)
AWHP-2 MIV-3
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Air-to-water heat pump
Yes
Yes
Water-to-water heat pump
No
No
Brine-to-water heat pump
No
No
Low-temperature heat pump
No
No
Equipped with a supplementary heater
Yes
Yes
Heat pump combination heater
No
No
Rated heat output under average conditions
(1)
Prated
kW
6
8
Rated heat output under colder conditions
Prated
kW
4
7
Rated heat output under warmer conditions
Prated
kW
8
13
Declared capacity for heating for part load at indoor tem
perature 20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW
6.8
9.0
T
j
= +2 °C
Pdh
kW
8.2
11.9
T
j
= +7 °C
Pdh
kW
9.0
12.9
T
j
= +12 °C
Pdh
kW
10.1
15.4
T
j
= bivalent temperature
Pdh
kW
6.2
8.3
Bivalent temperature
T
biv
°C
-10
-10
Degradation coefficient
(2)
Cdh
—
1.0
1.0
Seasonal space heating energy efficiency under average
conditions
ƞ
s
%
132
130
Seasonal space heating energy efficiency under colder
conditions
ƞ
s
%
113
113
Seasonal space heating energy efficiency under warmer
conditions
ƞ
s
%
167
161
Declared coefficient of performance or primary energy ra
tio for part load at indoor temperature 20 °C and outdoor
temperature
T
j
T
j
= -7 °C
COPd
-
1.82
1.88
T
j
= +2 °C
COPd
-
3.43
3.33
T
j
= +7 °C
COPd
-
4.54
4.34
T
j
= +12 °C
COPd
-
6.24
5.82
T
j
= bivalent temperature
COPd
-
1.45
1.54
Heating water operating limit temperature
WTOL
°C
60
60
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
Stand-by
P
SB
kW
0.013
0.013
Crankcase heater mode
P
CK
kW
0.055
0.055
Supplementary heater
Rated heat output
(1)
Psup
kW
0.0
0.0
Type of energy input
Electricity
Electricity
Other characteristics
Capacity control
Variable
Variable
3 Technical specifications
7611973 - v04 - 07032016
AWHP-2 MIV-3
15