Tab.7
Common specifications
Measurement
type
Unit
AWHP 4
MR
AWHP 6
MR-2
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Total dynamic
head at nominal
flow rate
kPa
58
49
29
11
11
–
–
Nominal air flow
rate
m
3
/hour
2100
2100
3300
6000
6000
6000
6000
Power voltage of
the outdoor unit
V
230
230
230
230
400
230
400
Start-up amper
age
A
5
5
5
5
3
6
3
Maximal amper
age
A
13
13
19
29.5
13
29.5
13
Acoustic power -
Inside
(1)
dB(A)
52.9
52.9
53.3
53.3
53.3
53.3
53.3
Acoustic power -
Outside
(1)
dB(A)
62.4
64.8
65.2
68.8
68.8
68.5
68.5
Acoustic pres
sure
(2)
dB(A)
41.7
41.7
43.2
43.4
43.4
47.4
47.4
Standby output
W
16.4
15
18
21.1
21.1
21.1
21.1
Refrigerant fluid
R410A
kg
2.1
2.1
3.2
4.6
4.6
4.6
4.6
Refrigerant fluid
R410A
equiv. kg
CO
2
4384
4384
6680
9603
9603
9603
9603
Refrigeration
connection (Liq
uid/Gas)
inch
1/4 - 1/2
1/4 - 1/2
3/8 – 5/8
3/8 – 5/8
3/8 – 5/8
3/8 – 5/8
3/8 – 5/8
Max. pre-loaded
length
m
10
10
10
10
10
10
10
Weight (empty) -
Outdoor unit
kg
42
42
75
118
118
130
130
Weight (empty) -
Indoor module
kg
52
52
52
55
55
55
55
(1) Noise radiated by the envelope - Test run in accordance with the NF EN 12102 standard, temperature conditions: air 7°C, water 55°C
(2) at 5 m from the appliance, free field
3.1.1 Other technical parameters
Tab.8
Technical parameters for heat pump space heaters (parameters declared for medium-temperature application)
AWHP-2 MIV-3
AWHP 4 MR
AWHP 6 MR-2 AWHP 8 MR-2
Air-to-water heat pump
Yes
Yes
Yes
Water-to-water heat pump
No
No
No
Brine-to-water heat pump
No
No
No
Low-temperature heat pump
No
No
No
Equipped with a supplementary heater
Yes
Yes
Yes
Heat pump combination heater
No
No
No
Rated heat output under average conditions
(1)
Prated
kW
2
4
6
Rated heat output under colder conditions
Prated
kW
2
4
6
Rated heat output under warmer conditions
Prated
kW
3
5
6
3 Technical specifications
7611973 - v04 - 07032016
AWHP-2 MIV-3