4
If the water temperature is lower than 4°C, the boiler starts up.
4
If the water temperature is higher than 10°C, the boiler shuts down
and the circulation pump continues to run for a short time.
4
If the water temperature in the storage tank is less than 4°C, it is
reheated to its set point.
CAUTION
4
The antifreeze protection does not function if the
appliance is switched off.
4
The integrated protection system only protects the
boiler, not the installation. To protect the installation,
set the appliance to
HOLIDAYS
mode.
The
HOLIDAYS
mode protects:
4
The installation if the outside temperature is lower than 3°C
(factory setting).
4
The room temperature if a remote control is connected and the
room temperature is lower than 6 °C (factory setting).
4
The domestic hot water tank if the tank temperature is lower
than 4 °C (the water is reheated to 10 °C).
To configure the holidays mode:
¼
See chapter: "Selecting the
operating mode", page 21.
5. Operating the appliance
AGC 10/15 AGC 15 AGC 25 AGC 35
27
15/03/2016 - 300026080-001-07