Modulens

EN

Gas fired floor-standing condensing boiler

AGC 10/15
AGC 15
AGC 25
AGC 35

User Guide

300026080-001-07

Summary of Contents for AGC 10

Page 1: ...Modulens EN Gas fired floor standing condensing boiler AGC 10 15 AGC 15 AGC 25 AGC 35 User Guide 300026080 001 07...

Page 2: ...ecifications 10 4 Description 12 4 1 Operating principle 12 4 1 1 Gas air setting 12 4 1 2 Combustion 12 4 2 Main parts 13 4 3 Control panel 14 4 3 1 Description of the keys 14 4 3 2 Description of th...

Page 3: ...1 General instructions 28 6 2 Periodic checks 28 7 Troubleshooting 30 7 1 Anti hunting 30 7 2 Messages Code type Bxx or Mxx 30 7 3 Faults Code type Lxx or Dxx 32 8 Energy savings 38 8 1 Energy saving...

Page 4: ...3 15 03 2016 300026080 001 07...

Page 5: ...be made by children without supervision CAUTION 4 The use of the boiler and system by you as the end user must be limited to the operations described in this User Manual All other actions may only be...

Page 6: ...ARNING Depending on the settings of the appliance 4 The temperature of the flue gas conduits may exceed 60 C 4 The temperature of the radiators may reach 85 C 4 The temperature of the domestic hot wat...

Page 7: ...eze protection 1 3 Liabilities 1 3 1 Manufacturer s liability Our products are manufactured in compliance with the requirements of the various applicable European Directives They are therefore deliver...

Page 8: ...the appliance and maintain it in good working order 4 Give all the instruction manuals to the user 1 3 3 User s liability To guarantee optimum operation of the appliance the user must respect the fol...

Page 9: ...angerous situation causing slight physical injury CAUTION Risk of material damage Signals important information Signals a referral to other instructions or other pages in the instructions 2 1 2 Symbol...

Page 10: ...PS Polypropylene hardly inflammable 4 PCU Primary Control Unit PCB for managing burner operation 4 PSU Parameter Storage Unit Parameter storage for PCBs PCU and SU 4 SCU Secondary Control Unit control...

Page 11: ...put Qnw DHW System Hi minimum maximum kW 3 1 15 0 3 1 15 0 5 2 29 3 6 5 35 1 Nominal input Qnw DHW System Hs minimum maximum kW 3 4 16 7 3 4 16 7 5 8 32 6 7 2 39 0 Heating efficiency under full load H...

Page 12: ...8 80 0 8 80 0 8 Water operating pressure PMS maximum kPa bar MPa 300 3 0 300 3 0 300 3 0 300 3 0 Water temperature maximum C 110 110 110 110 Operating temperature maximum C 90 90 90 90 Electrical cha...

Page 13: ...the exchanger guided by the pre mix channel 4 1 2 Combustion The burner heats the heating water circulating in the heat exchanger At a return temperature lower than around 55 C the flue gases cool dow...

Page 14: ...nd module 8 Water pressure sensor 9 Circulation pump 10 Hydroblock 11 3 way valve 12 Safety valve 13 Casing 14 Expansion vessel 15 Combined venturi and gas valve unit 16 Fan 17 Air intake silencer 18...

Page 15: ...Keys on which the function varies as and when selections are made F Rotary setting button 4 Turn the rotary button to scroll through the menus or modify a value 4 Press the rotary button to access th...

Page 16: ...j Back to the previous level ESC Back to the previous level without saving the modifications made t Manual reset n Flame output level C002705 A The whole symbol flashes The burner starts up but the fl...

Page 17: ...4 Flashing symbol Temporary override 4 Steady symbol Permanent override m Reduced mode The symbol is displayed when a NIGHT override reduced is activated 4 Flashing symbol Temporary override 4 Steady...

Page 18: ...utton 2 To access the menu press the rotary button To go back to the previous display press the key j 3 To select the desired parameter turn the rotary button 4 To modify the parameter press the rotar...

Page 19: ...o use the and keys instead of the rotary button bar 1 1 2 2 r c STD t v 0 2 4 6 8 10 12 14 16 18 22 24 20 pb AUTOxc r j L g m CURRENT PROG C Choice of the timeprogram applied C P4 a C002222 C 04 bar 1...

Page 20: ...ing system recommended hydraulic pressure between 1 5 and 2 0 bar 5 2 Reading out measured values The various values measured by the appliance are displayed in the MEASURES menu 1 To access user level...

Page 21: ...P 1 Water temperature in the second DHW tank connected to circuit A C TEMP SOL TANK 1 Temperature of the hot water produced by solar power TS C SOLAR COLL T 1 Solar panel temperature TC C SOLA ENERGY...

Page 22: ...20 to 80 C Maximum load temperature of the tank s solar zone 65 C SWIMMING P T B 1 HG 0 5 to 39 C Desired temperature for swimming pool B 20 C SWIMMING P T C 1 HG 0 5 to 39 C Desired temperature for...

Page 23: ...ated on the remote control option To force all circuits to run on AUTOMATIQUE mode select YES 1 The start and end days and the number of days are calculated in relation to each other 2 The parameter i...

Page 24: ...ress the rotary button to access the selected menu or confirm a value modification For a detailed explanation of menu browsing refer to the chapter Browsing in the menus page 17 3 Set the following pa...

Page 25: ...l Press the key 2 Select the menu TIME PROGRAM 4 Turn the rotary button to scroll through the menus or modify a value 4 Press the rotary button to access the selected menu or confirm a value modificat...

Page 26: ...right v Reduced mode selection Press key b v until the symbol v is displayed To select a reduced time range turn the rotary button to the right 10 When the times for the comfort mode have been select...

Page 27: ...nday Tuesday Wednesday Thursday Friday Saturday Sunday TIME PROG AUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday 5 4 Installation shutdown CAUTION Do not switch off the mains supply to th...

Page 28: ...ystem only protects the boiler not the installation To protect the installation set the appliance to HOLIDAYS mode The HOLIDAYS mode protects 4 The installation if the outside temperature is lower tha...

Page 29: ...nstalled follow the instructions delivered with the neutralisation system for cleaning and servicing of this system The boiler displays a message whenever maintenance is necessary 1 When the message R...

Page 30: ...this prevents the valves from seizing up 4 Clean the outside of the boiler using a damp cloth and a light detergent CAUTION Only a qualified professional is authorised to clean the inside of the boil...

Page 31: ...Description Checking solution B00 BL PSU ERROR The PSU PCB is incorrectly configured Parameter error on the PSU PCB 4 Contact the professional who takes care of maintenance of the appliance B01 BL BO...

Page 32: ...SCU PCB 4 Check that the gas valve is fully opened 4 Contact the professional who takes care of maintenance of the appliance B16 BL BAD SU The SU PCB is not recognised Wrong SU PCB for this boiler 4 C...

Page 33: ...r vent cycle is underway Switching the boiler on 4 Wait 3 minutes FL DRY B XX DAYS Floor drying is active XX DAYS Number of days floor drying remaining Floor drying is underway Heating on the circuits...

Page 34: ...takes care of maintenance of the appliance L04 DEF OUTLET S PCU Boiler temp too low Bad connection Sensor fault 4 Contact the professional who takes care of maintenance of the appliance No water circ...

Page 35: ...P MAX PCU Difference between the flow and return temperatures insufficient Bad connection Sensor fault 4 Contact the professional who takes care of maintenance of the appliance No water circulation 4...

Page 36: ...Bad connection Fan defective 4 Contact the professional who takes care of maintenance of the appliance L35 BACK BOIL FAIL PCU Flow and return reversed Bad connection Sensor fault 4 Contact the profess...

Page 37: ...alve is ensured Valves may be manually operated Reheating the domestic hot water remains ensured Bad connection Sensor fault 4 Contact the professional who takes care of maintenance of the appliance D...

Page 38: ...the SCU and PCU PCBs 4 Contact the professional who takes care of maintenance of the appliance D32 5 RESET ON OFF SCU 5 resets done in less than an hour 4 Switch the boiler off and switch back on 4 If...

Page 39: ...e control is available in the following versions 4 Wire 4 Radio The setting of the control panel and or of the remote control has a considerable influence on energy consumption A few tips 4 In the roo...

Page 40: ...er shall not be held responsible for any damage loss or injury caused by installations which do not comply with the following 4 applicable local laws and regulations 4 specific requirements relating t...

Page 41: ...en Appendix Information on the ecodesign and energy labelling directives...

Page 42: ...3 1 2 Ecodesign Directive 3 1 3 Technical data 3 1 4 Circulation pump 4 1 5 Disposal and Recycling 4 1 6 Product fiche Boiler space heaters 4 1 7 Product data sheet Temperature controls 4 1 8 Package...

Page 43: ...8 3 11 6 Seasonal space heating energy efficiency s 93 94 94 94 Useful efficiency at rated heat output and high temperature regime 2 4 89 5 89 5 89 4 89 3 Useful efficiency at 30 of rated heat output...

Page 44: ...s 10 Disconnect all pipes on the underside of the boiler 11 Dismantle the boiler 1 6 Product fiche Boiler space heaters Tab 2 Product fiche for boiler space heaters Product name AGC 10 15 AGC 15 AGC 2...

Page 45: ...cteristics Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C Seasonal space heating energy efficiency class of package Seasonal space heating energy efficiency of...

Page 46: ...ge without hot water storage tank II package with hot water storage tank 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1 00 0 7 1 00 1 00 1 The intermediate value...

Page 47: ......

Page 48: ...71 001 627 dedietrich bdrthermea cz IT DE DIETRICH THERMIQUE Iberia S L U www dedietrich calefaccion es C Salvador Espriu 11 08908 L HOSPITALET de LLOBREGAT 34 935 475 850 info dedietrich calefaccion...