3.3.13 Operating temperature should not exceed –15C to +55C.
3.3.14
NO
scheduled maintenance is required to ensure continued
airworthiness.
3.3.15
ESD
(Electro Static Discharge) guidelines shall be followed.
3.4
Wiring Requirements
3.4.1 Introduction
The installing agency shall supply and fabricate all external cables.
The length and routing of external cables shall be carefully studied
and planned before attempting installation of the equipment. Allow
adequate space for installation of cable and connectors. Avoid
sharp bends and placing cables near aircraft control cables.
Maintain a minimum clearance of three (3) inches from any control
cable. If wiring is run parallel to combustible fluid or oxygen lines,
maintain a separation of six (6)
inches between the lines.
3.4.2 Power Wires
All power and ground wires shall be in accordance with
NEMA WC
27500
,
MIL-W-22759
, or equivalent. Protect power wires with
circuit breakers or fuses located close to the electrical power
source bus.
3.4.3 Video Lines
Composite video connections shall be shielded coaxial cable in
accordance with the military specifications of
M17/94-RG179
.
3.4.4 DeCrane Aerospace Audio International’s Proprietary RS-485
Data Bus
3.4.4.1 The DVD-5x2-01-x is designed to interface with other
DeCrane Aerospace Audio International equipment via
DeCrane Aerospace Audio International’s proprietary RS-
485 serial data bus. The data bus shall
be implemented