Mechanical settings

Mechanical settings

To mount Adventus for the first time

Before mounting Adventus check,

• 

which footrest the wheelchair manufacturer recommends.

• 

that the distance between the front and rear tube of the footrest is as shown in the table 

below. 

Adventus is available in standard and in long design depending on the distance between the 

tubes of the footrest.

Adventus standard

Tube diameter 

[mm]

15

16

17

18

19

20

25

Distance 

[mm]

71,0–94,5 74,5–98,3

77,9–101,7

81,4–105,2

85,1–108,9

88,2–112,0

80-105

Adventus long

Tube diameter 

[mm]

15

16

17

18

19

20

25

Distance  

[mm]

90–135

93–138

97–142

100–145

104–149

107–152

100-145

Summary of Contents for Adventus

Page 1: ...Adventus User manual 2021 06 Rev1...

Page 2: ......

Page 3: ...oper use 4 Symbols 4 Warnings 5 Waste management 6 Labelling 7 Reuse 7 Warranty 8 Information on product safety and recalls 8 Product description 9 General 9 Technical data 9 Delivery scope 9 Overview...

Page 4: ...eading software read it aloud to you Purpose and normal use Adventus is an accessory designed to be connected to a manual wheelchair to facilitate mobil ity on uneven surfaces When Adventus is connect...

Page 5: ...ound in a safe environment together with an assistant until you feel confident about how Adventus works If you are driving on public roads even though you are not sure how to use Adventus you or other...

Page 6: ...oth If it is really dirty use a mild detergent solution Wipe with a soft cloth and air dry CAUTION Do not use corrosive or abrasive cleaning agents INFO Adventus is appropriately disinfected by using...

Page 7: ...te and a label showing the year of manufacture and month are placed on the underside of the frame Reuse When Adventus is to be transferred to a new user all technical documents must also be transferre...

Page 8: ...ns Nor does this warranty cover faults arising as a result of modifications to the device or continuous use under conditions other than those specified Scratches dulling and dirt on the surface of the...

Page 9: ...eel on Adventus is rotated the wheelchair s castors lift from the ground The angle in which Adventus is installed determens how much the castors of the wheelchair will lift from the ground Technical d...

Page 10: ...ngle adjustment of u profile I Steering link with adjustment screws E Link for angle adjustment J Framework Features The attachments B C are adjustable to suit different footrests With the angle adjus...

Page 11: ...and rear tube of the footrest is as shown in the table below Adventus is available in standard and in long design depending on the distance between the tubes of the footrest Adventus standard Tube dia...

Page 12: ...in the table below normaly results in lifting the front castors of the wheelchair 30 40mm from the ground INFO The settings in the table below can vary between different wheelchair models and manufact...

Page 13: ...el and lock the front tube of the footrest by folding down the locking lever A Tighten the screw K until the front attachment C locks against the footrest Tighten the locking screws L 7 Press the rear...

Page 14: ...the screw H in the steering link Make sure the wheel is aligned with the frame If this needs to be adjusted start by loosering the screw P Then loosen or tighten the adjustment screws I to align the w...

Page 15: ...the locking lever to open the front attachment 3 Fit Adventus in the middle of the footrest 4 Fold down the locking lever to its locked position 5 Turn the wheel to its rear position to lift the cast...

Page 16: ...Sida 16 18 To use Adventus Adventus User manual Transport of Adventus on wheelchair The transport holder is extra equipment Hang Adventus on the transport holder...

Page 17: ...required contact your retailer even if the fault is of a minor nature If parts are damaged or missing contact the retailer immediately Submit Adventus to the retailer for replacement or repair of part...

Page 18: ...Decon Wheel AB S dra Ekeryd 119 314 91 Hyltebruk Tel 46 0 345 40880 Fax 46 0 345 40895 E mail info decon se...

Reviews: