HD Rehab AB
, Tryffelslingan 4, 181 57 Lidingö, Sweden
tel. +46(0)8-767 04 80 [email protected] www.hdrehab.se
MD
Fixed back connector
Art. nr. 37761
Doc. nr. 96810-1 Rev A 2020-11-02
User manual /
Assembly instructions
Page 1 (2)
Intended use
Fixed back connector is used with HD Motion to set a fixed back angle between 90 and 105°.
It replaces the original gas spring and back recline control.
Parts included
Assembly
To be done by a duly qualified person.
Remove the seat cushion and seat plate.
Unscrew the inner half of the control housing
on the left side of the push bar. Leave the outer
half of the housing in place.
Remove the screw (a). Remove the lever (b) and
the arm (c). Unscrew the end sleeve (d) and
remove the cable.
Cover the holes in the housing with the cover
plug (e) and screw (f).
Reassemble the housing with the original
screws. Check that the control is sitting
properly and that the brake function has not
been affected.
1
2
3
1 x back connector
1 x cover plug
1 x screw M6
1
3
f
e
2
a
b
c
d