FILLING THE FUEL TANK

ONLY ADULTS MAY OPERATE THE ELECTRONICS OF THE DECOFLAME DENVER BASIC™.

In order to open the fuel lid, the fireplace needs to be plugged into a power socket. Press the 

 button 

for the lid to unlock . Open the lid of the fuel inlet, insert the funnel into the hole and fill in bioethanol. 
Once the fuel tank is filled by three-quarters, you will hear an acoustic signal. This tone will increase in 
intensity proportionally with fuel level. Once the tank is completely filled, the acoustic signal will become 
constant. Similarly, the lines indicating the fuel level on the control panel will gradually increase indicating 
to stop the filling process. Avoid spillage during filling. If you have spilled any bioethanol, use a paper 
towel in order to wipe off thoroughly any spilled liquid around the fuel inlet. 

Remove the funnel. Close the lid of the tank inlet. You can start the fire now by pressing the 

 button 

on the control panel.

NB: When filling the fuel tank, the electronics of the fireplace have to be switched on, in order to detect 
spillage.

NB: The ignition process will not start if any liquid is detected around the fuel inlet or if the lid for
the tank inlet is left open.

REFUELLING

 

The FUEL LEVEL lights will be blinking slowly when the tank will be empty.

DO NOT

 switch the electronics of the fireplace off. Wait until the flame is completely extinguished and the 

fireplace has cooled down (around 5-10minutes). When the the lights of the FUEL LEVEL indicator have 
stopped blinking, you can start the filling process. Press the  

 button for 5 seconds for the lid to unlock. 

Open the lid, insert the funnel in the hole and fill in bioethanol. 

IGNITION

Press the 

 button on the control panel. After a short while, the first flames will appear around the 

centre of the flame tray. Subsequently, it will take a short time until the fireplace will warm up and whole 
width of the flame tray is filled with flames. Once the flame tray shows flames throughout its complete 
width, the fire will be burning at a factory pre-set level. You can change the level by pressing the 

-+

 

buttons on the control panel. Once you have changed the flame level, please wait a couple of minutes 
before you adjust it further downwards or upwards, in order to give the system the necessary time to 
react to the changes made.

The control panel will go on stand-by (the lights on the control panel will turn off), if the flame level has 
not been changed for three minutes. In order to re-activate the control panel, you simply need to press 
the 

 button. 

The flame level will automatically decrease and cannot be increased to the initial level within the next 
15 minutes. During this process, the light on the control panel will be blinking within 10 seconds intervals.

ExTINGUISHING THE FLAMES

To switch off the fire at any time – also during the warming-up phase – press the 

 button on the control 

panel. The flames will disappear within a few minutes. You can leave the electronics on stand-by without 
pressing any further buttons now. You can also re-start the fire as described above immediately.

SwITCHING OFF

In order to switch off the electronics of the fire, switch the 

 button on the control panel.

Summary of Contents for Denver

Page 1: ...Copyright Decoflame ApS USER MANUAL DENVER BASIC ENGLISH ...

Page 2: ......

Page 3: ...E PACKAGING OF YOUR FIREPLACE IN CASE IT NEEDED TO BE SENT BACK TO THE FACTORY 1 content of the box 2 GENERAL information 3 POSITIONING and safety 3 1 placement under a tV 4 Maintenance 5 Installation 5 1 Creating a wall cut out 5 2 wall construction 5 3 step by step installation process 6 operating instructions 6 1 operating VIA CONTROL PANEL 6 2 operating via remote controller 6 3 operating VIA ...

Page 4: ...o choose a position for your fireplace which is not exposed to any draught as bioethanol is a volatile fluid In fact only the vapour of the bioethanol is burning when lit You should not touch the flames of the lit fireplace or blow into the flames You should also keep a distance of at least 30 cm moving past the fireplace as your movement may have an impact on the flames The electronics of your De...

Page 5: ...fireplace as the upwards drifting warm air might damage those Should you still want to create a setting incorporating a TV above the fireplace please follow the instructions below Figure 3 1 1 or ask Decoflame for further advice Figure 3 1 1 3 1 PLACEMENT UNDER A TV min 200mm min 800mm min 400mm min 100mm ...

Page 6: ...ge colour or structure This is to be considered normal wear and tear and does not constitute a product flaw or fault We recommend that if needed you clean all parts of your fireplace with a lint free cloth or kitchen paper towel and a non abrasive detergent some bioethanol or another alcohol based product Re garding polished steel surfaces use only a soft and clean cloth as the surfaces will easil...

Page 7: ...st be constructed of or at least covered with non flammable material like fibre plasterboards e g Fermacell GypRock FireLine or bricks Important The void above the fire place must not be openly connected to the void below the fireplace create a separation right above the top of the fireplace Stone Brick walls The cut out is made according to the drawing you have received with your fireplace The wa...

Page 8: ...ow the fire place Make sure to create a closed cavity for the section below and baseplate of the fire DO install the Denver Basic in a massive wall made of bricks stone or gas beton using the wall cut out dimensions mentiones on the previ ous page There are various possibilities of installing this fireplace model resting on top of the surrounding surface counter sunk by means of using the two stra...

Page 9: ...ut out and insert the plug into the socket If necessary switch on the socket Still holding the fire with the straps carefully sink it into the cut out STEP 3 After the fireplace is positioned as desired remove the straps by cutting them from under neath the fireplace Switch on the electronics using the button which will unlock the fuel lid Always check that the fireplace is connected to the power ...

Page 10: ...indicator have stopped blinking you can start the filling process Press the button for 5 seconds for the lid to unlock Open the lid insert the funnel in the hole and fill in bioethanol Ignition Press the button on the control panel After a short while the first flames will appear around the centre of the flame tray Subsequently it will take a short time until the fireplace will warm up and whole w...

Page 11: ...and the fireplace has cooled down around 5 10minutes In order to open the fuel lid hold the button down for 5 seconds for the lid to unlock bioethanol fuel All Decoflame bioethanol fireplaces are designed and manufactured exclusively for use with bioethanol of high purity 96 to max 97 5 DO NOT use any other fuel or materials or bioethanol of inferior qual ity as this will void your warranty Bioeth...

Page 12: ...ep nr 2 and give them differ ent names 4 Once you have selected your fireplace you can turn it on by pressing START If the fireplace has already been turned on us ing the control panel you can now monitor the fuel leven and the consumption 5 For the Turn Off Timer press the clock icon in the lower right corner To adjust the remaining time slide the dot to the left and right and select SET TIMER Th...

Page 13: ... 97 5 purity DO NOT mix bioethanol with other fuels DO NOT cover obstruct any of the ventilation slots of the fireplace DO NOT place any flammable materials or clothes near the fireplace DO NOT place any pebbles or stones on the e Ribbon Fire as these will crack and might cause injury or damage to the fireplace DO NOT place any ceramic logs or ceramic pebbles on the e Ribbon Fire as they will obst...

Page 14: ...oo high a tem perature inside the housing of Denver Basic Make sure that the fireplace has been installed according to the technical drawing and the installation manual and has suffi cient natural ventilation If the error keeps occuring contact Decoflame 45 9630 4800 hot evaporator The fire does not start or the fire turns to auto switch off mode The built in temperature sensor has detected too hi...

Page 15: ...15 Copyright Decoflame ApS ...

Page 16: ...tenholm 14 9400 Nørresundby Denamark tlf 45 9630 4800 info decoflame dk www decoflame com Decoflame reserves the right to make changes without notice RATING PLATE find the same rating plate on the back of the fireplace ...

Reviews: