Session Access
Code values = [02 to 07] for modulo 8
[02 to 15] for modulo 128
NOTE:
* After the last parameter is entered on the system request line, press ENTER.
* Insert a comma between successive parameters.
8.2.3Detach
This command is used to terminate a "waiting for call" condition on the Controller. If an
ANSWER command is issued, but a call has not yet been received, you can issue a
DETACH command to terminate the ANSWER mode.
Enter [D] on the system request line.
8.2.4Token Ring
If it is configured for Token-Ring, the Model 3494 Twinax Controller automatically begins
communication with the AS/400 system.
8.2.5Ethernet
If configured for Ethernet, the Model 3494 Twinax Controller automatically begins
communication with the AS/400 system.
8.2.6Changing the AS/400 System
The Model 3494 Twinax Controller can work alternatively with up to four AS/400 system
hosts. To establish communication with a different host from the one you are configured for
follow these steps:
1.
Your communication session must OFF or ended.
2. Press
SYS-REQ
to display the parameter [H1/H2/H3 or H4].
3. Choose the same number defined in ht Controller configuration for this host, and press
ENTER.
4. Access host according to line type.
6
Summary of Contents for 3000 Series
Page 1: ...Series 3000 STK3494 3494 User s Manual ...
Page 2: ......