4.4.8 Hold Time
The
"
Hold Time
"
value indicates the length of time in milliseconds
the speed is displayed after the target moves out of range . The
default
"Hold Time"
is 1000 milliseconds .
Figure 4.4.8
Hold Time
4.4.9 Update Rate
The selected speed format will be sent in whatever time interval (in
seconds) that you set . The "Update Rate
"
can be as low as 1 second
or as high as 8 seconds . The "Update Rate
"
and the amount of serial
port activity do not affect the measurement accuracy of the SVR
Dual™ . The default rate is 1 Second .
Figure 4.4.9
Update Rate
4.4.10 Sensitivity
The SVR Dual™ has a sensitivity range of 1-100 and is shipped with
the range setting at the (100) maximum . It is recommended that
the setting be left at 100 .
Figure 4.4.10
Sensitivity Setting
4.4.11 Water Distance Sensor Duty Cycle
The duty cycle of the water distance sensor can be configured to
cycle on/off as determined by the user . See Section 7 .4 for more
information .
Figure 4.4.11
Duty Cycle Setting