![Decatur Electronics GENESIS-VP User Manual Download Page 14](http://html.mh-extra.com/html/decatur-electronics/genesis-vp/genesis-vp_user-manual_2461628014.webp)
G
ENESIS
-VP™: User’s Manual
14
3. Displays
3.1
Number Segments
Left side: Three large digits
(888) display speeds and menu
categories.
Right side: Three small digits
(888) display speeds and
“select” values.
Displayed speed will be the
strongest signal, or, in fastest
mode, the next strongest signal
that is also going faster than the
strongest signal.
3.2
Status indicators (icons)
POWER
Indicates that power is on.
RFI
Indicates that there is radio frequency interference inhibiting the proper
operation of the unit. No new speeds will be displayed or transmitted via the
serial port while this icon is active. Locked speed will remain. Once the
condition no longer exists, the unit will operate properly. Possible causes of
this condition are patrol vehicle FM communications, proximity to radio
stations and other broadcast equipment.
LOW BAT
Indicates that the batteries need to be recharged. No new speeds will be
displayed or transmitted via the serial port while this icon is active. Locked
speed will remain.
LOCK
Indicates that the speed displayed in the secondary window is a stored value
that was previously displayed in the primary display window.
POWER RFI LOW BAT LOCK FAST
MPH
XMIT HOLD ERROR KPH
Figure 7:
Number Segments and
Status Indicators