3
2.
IMPORTANT INFORMATION
2.1
DESCRIPTION:
The Dean Super Runner
38 Series gas fryers are energy-efficient, gas-
fired units, design-certified by International
Approval Services, NSF International, and the
Canadian Gas Association and manufactured
to their basic performance and application
specifications.
All units are shipped completely assembled
with accessories packed inside the fryer
vessel. All units are adjusted, tested and
inspected at the factory before shipment.
Sizes, weights and input rates are listed in this
manual.
NOTE:
The on-site supervisor is
responsible for ensuring that operators are
made aware of inherent dangers of
operating a deep fat fryer, particularly
aspects of oil filtration, draining, and
cleaning of the fryer.
2.2 RATING PLATE:
This is attached to the
inside front door panel. Information provided
includes the BTU/hr input of the burners,
outlet gas pressure in inches WC and whether
the unit has natural or propane gas orifices.
2.3 PRE-INSTALLATION:
a. GENERAL: A licensed plumber should
install any gas-fired equipment.
1.
A manual gas shut-off valve must be
installed in the gas supply line ahead of
the fryer(s) for safety and ease of future
service.
2.
The Model SR38G gas fryers are
equipped with millivolt controls which
do not require electrical power
connections and do not have an
ON/OFF switch on the control panel.
b.
CLEARANCES: The fryer area must be
kept free and clear of all combustibles.
This unit is design-certified for the
following installations:
1.
Other than household use;
2.
Non-combustible floor installation
equipped with factory-supplied 6” (15
cm) adjustable legs or 5” (13 cm)
casters;
3.
With a minimum clearance of 6” (15
cm) side and 6” (15 cm) rear of
combustible construction.
c.
U.S. installations must meet:
American National Standard Institute
ANSI Z83.11
American Gas Association
8501 E. Pleasant Valley Road
Cleveland, OH 44131
National Electrical Code
ANSI/NFPA #70
American National Standard Institute
1430 Broadway
New York, NY 10018
NFPA Standards #96 and #211
National Fire Protection Association
470 Atlantic Avenue
Boston, MA 02110
e. Canadian installations must meet:
Canadian Electric Code c22.1, part 1
Canadian Standards Association
178 Rexdale Blvd.
Rexdale, ONT., M9W, 1R3
CAN 1-B149 Installation Codes
Canadian Gas Association
55 Scarsdale Road
Don Mills, ONT., M3B, 2R3
DANGER
THE FRYER MUST BE CONNECTED ONLY
TO THE TYPE OF GAS IDENTIFIED ON THE
ATTACHED RATING PLATE.