15
6.4
COMBINATION GAS VALVE:
Combination Gas
Valve
Is combination
gas valve manual knob
in the "OPEN"
position?
Turn the manual
knob "OFF".
Is a gas
cut-off valve present
between fryer and store's
incoming gas supply
line?
Check the gas
cut-off valve.
Is the gas cut-off
valve in the "OPEN"
position?
Are there any
other gas appliances
along this same gas supply line
between the cut-off valve and
the fryer?
Are any of
these other gas
appliance currently
working?
Problem is either in the
non-functional fryer or is in
the gas supply line near
the non-functioning fryer.
Contact your local
authorized Dean
servicer.
Contact your local
authorized Dean
servicer or local gas
supplier.
Turn the gas
cut-off valve
"OFF".
Turn the gas
cut-off valve to the
"OPEN" position.
Turn the fryer's
combination gas
valve manual knob to
"OPEN".
Problem is either in
the fryer or in the
incoming gas supply
line.
Contact your local
authorized Dean
servicer for
assistance!
Turn the manual
knob to the
"OPEN" position.
Attempt to
re-light the pilot.
Does the
pilot light?
Does pilot
remain lit when gas cock
manual knob is
released?
Check pilot flame
size and stability.
Go to page 14 and
follow flowchart "Pilot
Flame Adjustment".
Problem may be
a faulty
thermocouple.
Go to page 13 and
follow flowchart
"Set-Up".
Problem is either a
faulty pilot, gas valve,
or blockage in the gas
supply lines.
Contact your local
authorized Dean
servicer.
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Summary of Contents for Super Runner 38 Series