4-8
4.3.2.2 Filter Operation (cont.)
5.
Ensure the "Orange" handle in the filter
cabinet is closed and turn the filter power
switch "ON".
Note: The filter circuit is protected by a 7-amp
breaker located on the control panel of the filter
cabinet. If the circuit breaker trips, turn the filter
"OFF", reset breaker and continue filtering. If
the breaker continues to trip, ensure the correct
oil-return valve for the fryer being filtered is
"ON", and that there are no obstructions in the
return lines.
6.
If the filter system is equipped with the drain-
flush option, close the flush valve by pulling
the "Blue" handle located in the fryer cabinet
farthest from the filter cabinet.
7.
Oil should circulate through the filter and
back to the fryer vessel. Continue to use the
L-shaped brush to wash debris from the sides
and bottom of the fryer.
8.
Close drain valve when fryer is clean by
pushing the "Red" handle. Continue
pumping filtered oil back into the fryer.
Turn "Orange" handle to the right (handle end "UP")
to close hose connect valve.
Filter power switch and circuit protection breaker.
Pull "Blue" handle to close the drain-flush valve (if
applicable).