1.7.4 Replacing the High-limit Thermostat
(cont.)
4.
Remove two screws securing the high-limit
mounting-bracket. Do not disconnect wires from
high-limit at this time.
5.
Loosen and completely unscrew the compression
nut, then the pass-through nut on the frypot bottom.
Proceed to the next step before removing high-limit
from frypot.
6.
Remove high-limit mounting hardware. Older pots
may use a spring-bracket combination. Newer pots
will use mounting clips. Retain mounting hardware for
installation of new high-limit.
Compression nut unscrewed. Unscrew the
pass-through nut (arrow)
Remove screws (arrows) securing high-limit to fryer.
Older pots use spring-bracket combination.
Newer pots have mounting clips.