background image

7

WARNING!

IF THE MAIN BURNERS ARE

OPERATED WITH THE VESSEL

EMPTY, IRREPAIRABLE DAMGE

WILL OCCUR.  IF THE VESSEL IS

DAMAGED IN THIS WAY, THE

ENTIRE VESSEL ASSEMBLY MUST

BE REPLACED.

F.

 

Open the manual shut-off valve on the
incoming service line.

G.

 

Apply a lighted match or taper to the
pilot burner head.

H.

 

Turn the gas cock on the safety valve to
"Pilot", depress and hold the dial until
the pilot stays lighted when the dial is
released.  This may take a minute or
longer.

I.

 

If the pilot does not stay lit, depress the
dial and re-light it, holding the dial in
longer before releasing.  It may be
necessary to re-light the pilot several
times until the lines are purged of any
trapped air and a constant gas flow is
attained.

J.

 

When the pilot stays lit, turn the gas cock
dial to "ON".

K.

 

Turn the thermostat or "Thermatron"
controller to any "ON" setting and ensure
the main burners ignite from the pilot.

WARNING!

When lighting pilots and checking

for burner performance, do NOT

stand with your face close to the

burners.... They may ignite with a

"pop" and could flash back and

cause facial burns.

4.3  PILOT LIGHT (Electric Spark Ignition)

WARNING!

NEVER USE A MATCH OR TAPER

TO LIGHT THIS IGNITION SYSTEM!

A.

 

Turn electric power "OFF".

B.

 

Close the main gas valve on the
incoming line and wait five minutes for
any accumulated gas to disperse.

C.

 

Turn gas "ON".

D.

 

Set thermostat to desired temperature.  If
tank is water-filled, set thermostat at
195°F; if oil-filled, set thermostat at
350°F.

E.

 

Turn electrical power "ON".  If the unit
is equipped with a drain reset circuit,
ensure the switch is reset before
proceeding.

F.

 

The blower motor will come on,
activating the "sail" switch in the flue.
Power from the sail switch will pass
through the transformer to the spark
module.  The ignitor will spark and open
the gas control valve.  Once the burners
ignite, the spark will stop.  The
“Thermatron” controller or operating
thermostat now controls the fryer.

If the blower motor should fail, the main
gas valve will shut off the gas supply.

If the pilot flame fails, the ignition
module will shut down the unit and
lock out the system.  To restart, turn
electric power "OFF", wait about 30
seconds for the system to recycle
itself, then turn on the power.  Follow
steps (A) through (F) above.

Summary of Contents for 1824G

Page 1: ...quipment Service Association recommends using CFESA Certified Technicians Price 6 00 24 Hour Service Hotline 1 800 551 8633 819 5697 12 01 24G Series Flatbottom Gas Fryers Installation Operation Manual Models 1824G 2424G Parts List Included ...

Page 2: ...M MUST BE EMPTIED INTO A FIREPROOF CONTAINER AT THE END OF FRYING OPERATIONS EACH DAY SOME FOOD PARTICLES CAN SPONTANEOUSLY COMBUST IF LEFT SOAKING IN CERTAIN SHORTENING MATERIAL DANGER THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND OR BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM Operation installation and servicing of this product could expose you to airborne par...

Page 3: ...ESCRIPTION AND SPECIFICATIONS 1 2 PRE INSTALLATION 2 3 RECEIVING AND INSTALLING THE FRYER 3 4 INITIAL START UP 5 5 DAILY OPERATION 8 6 CLEANING MAINTENANCE 9 7 TROUBLESHOOTING 10 8 RECOMMENDED SPARE PARTS PARTS LIST 12 9 FACTORY SERVICE PARTS ORDERING 12 10 SPECIFICATIONS 17 11 WIRING DIAGRAMS 18 ...

Page 4: ...sfer ducting on the vessel bottom for efficient heating of oil without scorching 1 2 BODY CONSTRUCTION Base units come with painted cabinetry or optional stainless steel Base units come with 6 adjustable legs or optional 5 casters Multiple units come with casters 1 3 OPERATING CONTROLS 24G Series Flatbottom Fryers come with an operating thermostat for reliable temperature control Fryers can also b...

Page 5: ...when equipped with the factory supplied six inch legs or casters and C For installation without legs on a non combustible curb or platform 2 3 STANDARDS Installation must be planned in accordance with all applicable state and local codes taking into account the following standards A The fryer and it s individual shut off valve must be disconnected from the gas supply piping system during any press...

Page 6: ...ood construction and installation 3 RECEIVING INSTALLING THE FRYER 3 1 UNPACKING Check that the container is upright Use outward prying no hammering to remove the carton Check the fryer s for visible damage if such damage has occurred do not refuse shipment Contact the carrier and file the appropriate freight claims Do not contact the factory as the responsibility for shipping damage is between th...

Page 7: ...l valve performs that function unless the incoming pressure is in excess of 1 2 PSI in which case a step down regulator will be required C 24G Series fryers can be connected to either natural or propane gas depending on the customer s ordering instructions The correct combination gas valve and orifices are installed at the factory for the appropriate gas and while the valve can be adjusted in the ...

Page 8: ...move any protective plastic covering prior to operation Wash and thoroughly dry any accessories shipped with the unit Close the drain valve completely and remove the crumb screen Ensure the screws holding the thermostat and limit control sensing bulbs into the vessel are properly connected and tight 4 2 INITIAL PILOT LIGHT 24G Series gas fryers are tested adjusted and calibrated before leaving the...

Page 9: ... ignite with a pop and could flash back and cause facial burns 4 3 PILOT LIGHT Electric Spark Ignition WARNING NEVER USE A MATCH OR TAPER TO LIGHT THIS IGNITION SYSTEM A Turn electric power OFF B Close the main gas valve on the incoming line and wait five minutes for any accumulated gas to disperse C Turn gas ON D Set thermostat to desired temperature If tank is water filled set thermostat at 195 ...

Page 10: ...n an approved container or cut it into small pieces and pack it into the frying vessel leaving no air spaces and being careful not to disturb the sensing bulbs Melt the shortening either with the melt cycle control or by turning the burners ON for about 5 10 seconds OFF for 1 minute etc until the shortening is melted If the oil starts to smoke during the melt cycle shorten the ON cycle and lengthe...

Page 11: ...compound should be filtered at least daily as described in the instructions packed with the filter or even more frequently if cooking is heavy This assures the longest life possible for the frying compound gives a better taste to the food being prepared and minimizes flavors being transferred from batch to batch CAUTION When filtering never leave the filter unattended The action of the oil moving ...

Page 12: ...n the heat down and let the mixture stand until deposits and or carbon spots can be rubbed off with the Teflon brush E Scrub the tank walls bottom and heating elements then drain the vessel and rinse in clean clear water F Refill with clean clear water and boil again G Drain rinse and dry thoroughly H Refill with cooking oil or frying compound as directed in the above section 6 4 PERIODIC Have the...

Page 13: ...e lead from pilotstat power unit bushing and clean with fine sandpaper Also check that bushing is clean 3 Thermocouple possibly defective replace 4 Pilot flame may be either too high or too low Adjust flame by turning pilot flow adjustment 5 Pilot flame of proper size but unstable Flame wavers and does not envelop the thermocouple completely at all times Check for drafts which might be caused by a...

Page 14: ...he flue and lodged in the blower wheel preventing it from turning Clean out flue and blower wheel 2 Blower motor may have overheated and shut off on thermal overload This condition will correct itself when motor cools 20 minutes If problems with blower overheating persist call for service 3 If fryer is equipped with a Thermatron Controller the temperature probe or the Thermatron board may be defec...

Page 15: ...commended that one each of the following parts be kept in local stock High limit control Combination gas valve Thermocouple Operating thermostat if applicable Spark module if so equipped 9 FACTORY SERVICE PARTS ORDERING 9 1 SERVICE PROBLEMS Call the 800 number on the cover of this booklet for the location of your nearest Maintenance Repair Center or contact the factory direct Always give the model...

Page 16: ... 16 17 18 19 20 21 22 23 24 25 26 28 27 29 Some units have Thermatron board mounted behind rocker switch cover in cabinet 30 31 32 34 33 35 13 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 55 Some units have Thermatron board mounted in control panel 54 51a ...

Page 17: ...13 Duct Door Access 210 1365 210 1365 14 Spreader Side Flame 210 1409 210 1409 15 Baffle Secondary Air 823 3190 823 3190 16 Insulation Inswool 816 0535 816 0535 17 Back Fire Box 200 2731 200 1391 18 Guard Fire 823 3170 823 3170 19 Guard Temperature High Limit Probe 200 1411 200 1411 20 Divider Vessel 24103 24103 21 Tray Crumb 24003 823 3189 22 Panel Side LH 823 3168 823 3168 Panel Side RH 823 3169...

Page 18: ...6 820 0136 Thermatron Retro Kit 24233 1 24233 1 Potentiometer Assembly G0 807 3536 807 3536 Interface Board G0 Thermatron 115VAC 807 3536 807 3536 Knob G0 Thermatron Control 816 0534 816 0534 42 Thermostat Operating 807 3515 807 3515 43 Knob Operating Thermostat 816 0546 816 0546 44 Thermostat High Limit 435 F Man Reset 807 3559 807 3559 Thermostat High Limit 435 F Auto Reset 807 3516 807 3516 45 ...

Page 19: ...use Holder 807 1321 807 1321 Fuse 2 Amp 807 3592 807 3592 Additional Components Not Illustrated Bracket Batter Pan 24 0097 24 0098 Cover Vessel 106 1264SP 106 1620SP Bracket Mercury Switch 24 0256 24 0256 Clamp Mercury Switch Probe 210 2620 210 2620 Switch Mercury 44900 44900 Transformer 24V 807 3571 807 3571 Circuit Breaker 807 3577 807 3577 Not Illustrated ...

Page 20: ...VERALL HEIGHT 45 35 WORK HEIGHT 35 18 x 24 FRYING AREA 24 x 24 45 70 Lbs OIL CAPACITY 65 90 Lbs 120 000 GAS RATING BTU 120 000 120V 60 1Ø 2 0A ELECTRICAL RATING 120V 60 1Ø 2 0A OVERALL WIDTH OVERALL DEPTH WORK HEIGHT OPTIONAL CASTERS OVERALL HEIGHT MODELS 1824G 2424G GAS FRYERS ...

Page 21: ...LU BLK Operating Thermostat High Limit Thermostat Air Prover MOTOR BLK BLK WHT BRN 3 2 8 7 LIGHT 120V 2 3 4 1 BLK GRN WHT 2 AMP FUSE BLK POWER SWITCH WHT WHT 8 120 VAC 24 VAC COIL 7 8 5 6 3 4 1 2 TRANSFORMER RESET SWITCH 7 PUR BRN SAFETY SWITCH IF USED VALVE SWITCH RED YEL BRN 115V POWER SUPPLY 7 2 3 RELAY BRN 2 8 3 ...

Page 22: ...GAS VALVE THERMOCOUPLE BLU 2 3 4 1 BLK WHT BLK WHT ORG WHT ORG WHT WHT BRN WHT BLK GRN WHT BRN RED PUR YEL ORG PUR YEL ORG BLK BLK GRN WHT ORG WHT WHT BRN GRN WIRING FRYER WITH THERMATRON ORG WHT 7 2 3 8 BRN LIGHT 120V 2 3 4 1 BLK GRN WHT 2 AMP FUSE ORG POWER SWITCH WHT WHT 7 2 3 8 120 VAC 24 VAC COIL 7 8 5 6 3 4 1 2 TRANSFORMER RESET SWITCH BRN PUR BRN SAFETY SWITCH IF USED VALVE SWITCH RED YEL B...

Page 23: ...NITOR FLAME SENSOR GAS VALVE OPERATING THERMOSTAT TRANSFORMER 115 24V BLK BLK WHT WHT BRN BLK WHT BRN 3 2 8 7 GRN 115V POWER SUPPLY 2 AMP FUSE POWER SWITCH LIGHT LIGHT 120V 2 3 4 1 BLK GRN WHT 2 AMP FUSE BLK POWER SWITCH WHT WHT 8 120 VAC 24 VAC COIL 7 8 5 6 3 4 1 2 TRANSFORMER RESET SWITCH PUR BRN SAFETY SWITCH IF USED VALVE SWITCH RED YEL BRN 115V POWER SUPPLY 7 2 3 RELAY BRN 8 7 2 3 ...

Page 24: ... WHT BRN WHT BLK GRN WHT BRN RED PUR YEL ORG PUR YEL ORG BRN BLK BLK GRN WHT ORG WHT ORG WHT WHT BRN GRN WIRING FRYER WITH THERMATRON ELECTRONIC IGNITION DSI IGNITION MODULE 24V HIGH TENSION LEAD SPARK IGNITOR FLAME SENSOR GAS VALVE WHT BRN WHT GRN 7 8 2 3 WHT WHT BLK BLK POWER SWITCH LIGHT VAC 120 PUR BRN VALVE SWITCH RED AC 24V YEL TRANSFORMER BRN 8 7 3 2 1 6 5 4 GRN 2 AMP FUSE LIGHT OPTIONAL SA...

Page 25: ...t Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 310 327 3343 FAX Tech Support 1 318 219 7135 Price 6 00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 819 5697 12 01 ...

Reviews: