29
7.2 Uploading data from an external memory unit (UPLOAD)
1. Scroll down the parameters with
and
keys until you visualize P012;
2. Press the
key, the display visualizes the word “
” fl ashing;
3. Press the
again and continue pressing for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the
key as soon as the word “
” stops fl ashing;
All the control panel confi gurations (TYPE, parameters, remotes, operators stroke, etc..) contained in the external memory unit are
uploaded in the connected control panel;
5.
At the end of the operation display returns to P012.
WARNING
If you are not connected to any MEMONET units or if the connecting cable is disconnected during the data transfer operation,
the display will visualize
, then the control unit is entirely reset and the display shows the word “TYPE” fl ashing.
Refer to the MEMONET instruction to restore command unit functioning.
8 Inputs confi guration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can confi gure each input for the
operation desired (eg. START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the
and
to see that corresponding
to the desired one:
● P018=for INPUT 1;
● P019=for INPUT 2;
2. Confi rm by pressing on the
key to get access to the parameter (eg.
P018);
3. Scroll down with the
and
, keys to set the value corresponding to
the desired operation (refer to table “Input Confi guration parameters” on
page 32);
4. Confi rm by pressing on the
key (display shows again P018).
5. Execute the new connection to the input just reconfi gured.
9 Programming complete
WARNING
At the end of the programming procedure,
re-introduce Jumper J4, until “- - - -” is shown on the display
and close the lid of
the electric box. The automatism is now in stand-by for normal operating commands.
Summary of Contents for ADVANCE
Page 20: ...18 ...
Page 38: ...36 ...
Page 56: ...54 ...
Page 74: ...72 ...
Page 92: ...90 ...
Page 110: ...108 ...
Page 128: ...126 ...
Page 146: ...144 ...
Page 149: ...147 max 30 ...
Page 150: ...148 min 1 5m ...
Page 151: ...149 ...
Page 154: ......
Page 163: ......