24
7 STANDARD PROGRAMMING
To access the control unit programming functions,
remove the
lid from the electric box and remove Jumper J4
from the bo-
ard.
NORMAL
FUNCTIONING
PROGRAMMING
MODE
1 Motors stroke learning
1. Scroll the parameters with the
and
keys until the screen reads P003;
2. Access the parameter by pressing the
button;
3.
With fl ashing “
” , check correct movement of the door by operating on the
(
OPEN
) and
(
CLOSE
) keys;
If the movement does not correspond to that envisioned, disconnect the power supply, invert the motor cables and repeat the
operation.
4. Press the
button, the screen shows the fl ashing “
”;
5. Press the
key again and release it as soon as “
” is fi xed. Start an automatic search manoeuvre for the closing limit stop with
slow movement.
A slow opening movement will follow to memorise the door travel along with an opening and closing manoeuvre at normal speed to
map the force necessary during travel.
6. The last movement closes the door and P003 re-appears on the display at the end of the procedure.
2 Deletion of all transmitters
1. Scroll down the parameters until you visualize P004;
2. Confi rm by pressing on the
key;
3. When “
” is fl ashing, press the
key for a few sec-
onds;
4. Release the
key as soon as “
” stops fl ashing;
5. All memorized transmitters have been deleted (display
shows again P004).