Owner’s manual – ESQUIRE 35
21 of 37
Active corrosion fuses (2x 1Amp)
Webasto heater (20Amp + 1Amp)
Aft bilge pump (5Amp)
The automatic circuit breakers in the main switchbox are divided into four (4)
sections, fused by individual strip fuses located in a fuse box underneath the main
switchbox.
5.7 Navigational equipment
Esquire 35 is equipped with a
Garmin
navigation
system. All individual equipment is connected by a
NMEA2000 network as shown in the schematic. There is
an extra NMEA2000 link supplied in the Volvo EVC
system to make it possible to read engine date on the
GPSMAP screen.
IMPORTANT
Familiarize yourself with local regulations on the use and registration of your
communication devices VHF.
See the Garmin Operator’s Manuals for specific information on operating and
use.
3
0
A
3
0
A
3
0
A
3
0
A
Main fuse 100A
Strip fuses
NOTICE
Beware that the VHF system
fitted on board, must be
operated by a person holding
a Radio Operator's Certificate