Figur 2 - Overview of I-DE

Introduction and summary

Introduction

The I-DE is a multifunctional position sensor. It is important that the I-DE is connected and used correctly.

This user manual discusses various components in great depth. It explains how the I-DE should be fully connected, used 

and calibrated.

Summary

The I-DE can be operated easily using a push button. The current status of the I-DE is indicated by various LED flash 

patterns.

The stroke of the motor gearbox can be calibrated in the I-DE. Using an analogue current signal, the I-DE is able to report 

the position of the motor gearbox back to the process computer or control box. The I-DE also features a digital output. 

When the motor gearbox rotates, the I-DE outputs digital A/B/Z signals. The position and motion of the motor gearbox 

can be monitored easily using the I-DE. 

To make all of the above functions possible, the I-DE has a large number of connection points. Figure 2 shows a diagram 

of the I-DE. Table 1 then lists the eight connection points on the I-DE.

Pin No. Function
1

Power supply 24 V AC/DC

2

Power supply GND

3

Output current (0-20 mA / 4 - 20 mA)

4

Reference GND

5

Reset

6

Signal A (HTL / TTL / Open Collector

7

Signal B (HTL / TTL / Open collector

8

Signal Z (HTL / TTL / Open Collector)

BUTTON

Summary of Contents for I-DE

Page 1: ...Let s Gear Up User manual I DE VERSION 1 2020 08 03 ...

Page 2: ...perpatronen led 7 3 Het gebruik 8 3 Het gebruik 9 3 2 Stroomdiagram I DE 9 3 3 1 Stroomuitgang 9 3 3 2 A B Z uitgangen 9 3 Het gebruik 10 3 4 Foutmode10 3 5 Instelmode 10 3 Het gebruik 11 3 5 1 Positie I DE resetten Hoofdmenu 1 11 I DE installation example The I DE is equipped as standard with a thick O ring which ensures that it is properly secured in the motor gearbox housing In some cases howev...

Page 3: ...perpatronen led 7 3 Het gebruik 8 3 Het gebruik 9 3 2 Stroomdiagram I DE 9 3 3 1 Stroomuitgang 9 3 3 2 A B Z uitgangen 9 3 Het gebruik 10 3 4 Foutmode10 3 5 Instelmode 10 3 Het gebruik 11 3 5 1 Positie I DE resetten Hoofdmenu 1 11 I DE installation example The I DE is equipped as standard with a thick O ring which ensures that it is properly secured in the motor gearbox housing In some cases howev...

Page 4: ...n during action LED colour pattern after action 1 Push and hold the button for 10 seconds wait until the LED lights up red Reset to factory settings 2 Push and hold the button for 4 seconds wait until the red quick flashing LED has stopped again Activate the I DE s calibration mode 3 Place motor gearbox in start position Determine minimum start position inlet valves 4 Push and hold the button for ...

Page 5: ...ke of the motor gearbox can be calibrated in the I DE Using an analogue current signal the I DE is able to report the position of the motor gearbox back to the process computer or control box The I DE also features a digital output When the motor gearbox rotates the I DE outputs digital A B Z signals The position and motion of the motor gearbox can be monitored easily using the I DE To make all of...

Page 6: ...h terminal block The 24V AC DC supply has to be wired to connections 3 and 9 of the limit switch terminal block For more information we refer you to the ma nual for the GW motor gearbox Should you have a different power supply to the limit switch then an additional relay P IDE RST 230 01 can be used to generate a signal for the reset input Note Connection of a 230V AC supply to any of the terminal...

Page 7: ...g diagram in figure 4 As should be clear from figure 4 it is absolutely not per mitted to connect an additional external power supply to the current output 2 4 A B Z outputs If HTL or TTL is selected for the A B Z out puts then the wiring diagram in figure 5 should be used If Open Collector is selected for the A B Z out puts then the wiring diagram in figure 5 should be supplemented with the wirin...

Page 8: ...reen orange once The LED will flash in the specified colour once and then go off for a short period of time Repeatedly flashing red green orange twice The LED will flash in the specified colour twice and then go off for a short period of time Repeatedly flashing red green orange three times The LED will flash in the specified colour three times and then go off for a short period of time Repeatedly...

Page 9: ... 01 2021 9 3 Operation Seconds in diagram Hold down push button LED Step 1 sec between 0 2 sec continue to next vertical step 2 sec between 2 4 sec save continue to next horizontal step 4 sec between 4 10 sec from factory reset to quick start from main menu to normal operation 10 sec between 10 15 sec to factory reset Figure 7 I DE flow diagram ...

Page 10: ...01 2021 10 3 Operation Seconds in diagram Hold down push button LED Step 1 sec between 0 2 sec continue to next vertical step 2 sec between 2 4 sec save continue to next horizontal step 4 sec between 4 10 sec from factory reset to quick start from main menu to normal operation 10 sec between 10 15 sec to factory reset Figure 7 I DE flow diagram ...

Page 11: ...sponse to each two second action on the push button Situations during normal operation The I DE has not been calibrated and can be used as a digital encoder The I DE has been calibrated and can be used as both a digital and analogue encoder 3 3 1 Output current Depending on the settings and position of the motor gearbox the I DE will when calibrated output a current of bet ween 0 and 20 mA or 4 an...

Page 12: ...n Make adjustments where necessary After correction the power can be restored to the I DE and the I DE should function correctly 3 5 Calibration mode The I DE can be calibrated via the main menu The main menu can be accessed from Normal operation or from Error mode The main menu comprises the following elements Reset I DE position Set I DE current output start position Calibrate I DE I DE A B Z mo...

Page 13: ... I DE is currently in main menu 1 see Figure 7 If the I DE is in Normal operation or Error mode Main menu 1 can be accessed by pushing and holding the button for two seconds Reset I DE position The I DE is in Main menu 1 Push and hold the button for two seconds then release After 2 seconds this LED pattern will be displayed Turn the motor gearbox to the motor gearbox start position Push and hold t...

Page 14: ...f the stroke only The I DE furthermore allows the reset position to be configured at any random point in the GW motor gearbox s stroke For further information on these options please contact De Gier sales degier nl NOTE The step by step plan below assumes that the I DE is currently in main menu 1 see Figure 7 If the I DE is in Normal operation or Error mode Main menu 1 can be accessed by pushing a...

Page 15: ...ill n the selected Adjust I DE current range The I DE is in Main menu 1 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 2 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 3 Push and hold the button for two seconds then release After 2 seconds this LED pattern will be displayed...

Page 16: ... the position at which the I DE starts to output a current Users can choose from 2 options option 1 the start position at 0 mA or 4 mA option 2 the start position at 20 mA To do this follow the steps below NOTE The step by step plan below assumes that the I DE is currently in main menu 1 see Figure 7 If the I DE is in Normal operation or Error mode Main menu 1 can be accessed by pushing and holdin...

Page 17: ...r less than one second This LED pattern will be displayed The I DE is in Main menu 3 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 4 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Push and hold the button for two seconds then release After 2 seconds this LED pattern will be displaye...

Page 18: ...h is optional When a limit switch is used its use allows a reset position to be saved at any point in the calibrated stroke see section 3 5 2 The reset position corresponds to the start or end position of the GW motor gearbox as standard If the limit switch is activated while the GW motor gearbox is rotating the I DE will output the value corresponding to the calibrated reset position 3 8 Restorin...

Page 19: ...ermore allows the reset position to be configured at any random point in the GW motor gearbox s stroke For further information on these options please contact De Gier sales degier nl NOTE The step by step plan below assumes that the I DE is currently in main menu 1 see Figure 7 If the I DE is in Normal operation or Error mode Main menu 1 can be accessed by pushing and holding the button for two se...

Page 20: ...t range The I DE is in Main menu 1 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 2 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 3 Push and hold the button for two seconds then release After 2 seconds this LED pattern will be displayed The I DE is now in Submenu 3A If 4 2...

Page 21: ... the position at which the I DE starts to output a current Users can choose from 2 options option 1 the start position at 0 mA or 4 mA option 2 the start position at 20 mA To do this follow the steps below NOTE The step by step plan below assumes that the I DE is currently in main menu 1 see Figure 7 If the I DE is in Normal operation or Error mode Main menu 1 can be accessed by pushing and holdin...

Page 22: ...r less than one second This LED pattern will be displayed The I DE is in Main menu 3 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 4 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Push and hold the button for two seconds then release After 2 seconds this LED pattern will be displaye...

Page 23: ...ermore allows the reset position to be configured at any random point in the GW motor gearbox s stroke For further information on these options please contact De Gier sales degier nl NOTE The step by step plan below assumes that the I DE is currently in main menu 1 see Figure 7 If the I DE is in Normal operation or Error mode Main menu 1 can be accessed by pushing and holding the button for two se...

Page 24: ...t range The I DE is in Main menu 1 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 2 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 3 Push and hold the button for two seconds then release After 2 seconds this LED pattern will be displayed The I DE is now in Submenu 3A If 4 2...

Page 25: ... the position at which the I DE starts to output a current Users can choose from 2 options option 1 the start position at 0 mA or 4 mA option 2 the start position at 20 mA To do this follow the steps below NOTE The step by step plan below assumes that the I DE is currently in main menu 1 see Figure 7 If the I DE is in Normal operation or Error mode Main menu 1 can be accessed by pushing and holdin...

Page 26: ...r less than one second This LED pattern will be displayed The I DE is in Main menu 3 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Main menu 4 Push and hold the button for less than one second This LED pattern will be displayed The I DE is in Push and hold the button for two seconds then release After 2 seconds this LED pattern will be displaye...

Reviews: