2.2 Reset input
The reset input has to be connected. This can be done by means of an external signal or by means of one of the li-
mit switches, as long as this limit switch is powered by the same power supply as the I-DE. See figure 3 for the wiring
diagram. For limit switch 1 use connections 8 and 9 on the limit switch terminal block. If you want to use limit switch
2 as a reset signal you have to use connections 2 and 3 on the limit switch terminal block. The 24V AC/DC supply has
to be wired to connections 3 and 9 of the limit switch terminal block. For more information we refer you to the ma-
nual for the GW motor gearbox. Should you have a different power supply to the limit switch then an additional relay
(P.IDE,RST,230.01) can be used to generate a signal for the reset input.
Note!
Connection of a 230V AC supply to any of the terminals of the I-DE is not permitted.
2 Wiring Diagram
For the proper functioning of the I-DE it is important that it is connected correctly. The connection of
the power supply, current output, A/B/Z output and reset input are discussed in this chapter.
2.1 Power supply
The I-DE has to be connected to the ower supply as indicated in figure 3.Both a DC- or AC- 24V signal can be
connected to the power inlet.