background image

     

 

  2 / 16 

 

WWW.DDTOP.COM 

 

前  言 

Preface 

 

感谢您选择丹东通博电器(集团)有限公司的产品。 
Thank you for choosing the products of Dandong Top Electronics Instrument (Group)Co.,Ltd. 
 
本使用说明书给您提供有关安装、连接和调试以及针对维护、故障排除和贮存方面的重要信息。请
在安装调试前仔细阅读并将它作为产品的组成部分保存在仪表的近旁,供随时翻阅。 
This  operation  manual  provides  you  with  important  information  on  installation,  connection  and 
commissioning  as  well  as  on  maintenance,  troubleshooting  and  storage.  Please  read  it  carefully 
before installation and commissioning and keep it as part of the product near the meter for easy 
reading. 
 
并可通过

www.ddtop.com

入版本号下载本说明书。 

This manual can be downloaded by entering the version number at 

www.ddtop.com

 

 
如未遵照本说明书进行操作,则本仪表所提供的防护可能会被破坏。 
If the instructions are not followed, the protection provided by the meter may be destroyed. 
 
商标、版权和限制说明 
Trademark, Copyright and Restriction Instructions 
通博、通博电器、通博泵业、DDTOP、均为公司的注册商标。 
Dandong Top Electronics Instrument (Group) Co.,Ltd.®, Dandong Top Pump Co., Ltd.®, DDTOP® 
are registered trademarks of the company. 
 
本仪表的性能规格自发布之日起生效,如有更改,恕不另行通知。丹东通博电器(集团)有限公司
有权在任何时候对本说明书所述的产品进行修改,恕不另行通知。 
The  performance  specifications  of  the  meter  are  effective  as  of  the  date  of  publication  and  are 
subject to change without notice. Dandong Top Electronics Instrument (Group)Co.,Ltd. reserves the 
right to modify the products described in this manual at any time without prior notice. 
 
质保 
Quality Assurance 
丹东通博电器(集团)有限公司保证所有刮板流量计自出厂之日起,一年之内无材料和制造工艺方
面的缺陷。 
Dandong  Top  Electronics  Instrument  (Group)  Co.,Ltd.  guarantees  that  all  glass  plate  level  gauge 
have no defects in materials and manufacturing processes within one year from the date of delivery. 
 
在质保期内,如产品出现质量问题而返回,提出的索赔要求经制造厂检验后确定属于质保范围内,
则丹东通博电器(集团)有限公司负责免费为买方(或业主)维修或更换。 
During  the  warranty  period,  if  the  product  returns  with  quality  problems  and  the  claim  is 

Summary of Contents for ULG

Page 1: ...1 16 WWW DDTOP COM ULG ULG S BI COLOR GLASS TUBE LEBEL GAUGE ULG Operation Manual ULG DT JS 1010 2018 A...

Page 2: ...er may be destroyed Trademark Copyright and Restriction Instructions DDTOP Dandong Top Electronics Instrument Group Co Ltd Dandong Top Pump Co Ltd DDTOP are registered trademarks of the company The pe...

Page 3: ...dong Top Electronics Instrument Group Co Ltd does not provide any express or implied warranty Quality ISO9001 Dandong Top Electronics Instrument Group Co Ltd has passed the ISO9001 quality system cert...

Page 4: ...onal Schematic 7 5 9 5 Unpacking and Inspection 9 5 1 9 5 1 Unpacking Inspection Notice 9 5 2 11 5 2 Check Content 11 6 11 6 Installation 11 6 1 11 6 1 Installation Tool 11 6 2 11 6 2 Installation Tec...

Page 5: ...able local national international standards codes and procedures Be sure to install the equipment in Intrinsically safe or non flammable site operating procedures 1 2 1 2 Process leaks can cause serio...

Page 6: ...alve 2 2 Compression Body 3 3 Socket Head Cap Screws 4 4 Graphite Filler 5 5 Quartz Glass Tube 6 6 Ruler 2 2 2 2 Operating Principle According to the principle of the connector the level in the contai...

Page 7: ...dity 20 3 3 Technical Characteristics 3 1 3 1 Main Performance 3 1 1 JB T9243 3 1 1 Product Performance Standards JB T9243 glass tube level gauge 3 2 3 2 Main Parameters 3 2 1 0 3MPa 3 2 1 Needle valv...

Page 8: ...Schematic S1 Glass Tube Level Gauge 2 2 S2 Figure 2 2 Dimensional Schematic S2 Glass Tube Level Gauge 2 3 S4 Figure 2 3 Dimensional Schematic S4 Glass Tube Level Gauge 2 4 S5 Figure 2 4 Dimensional S...

Page 9: ...9 16 WWW DDTOP COM 2 3 S4 Figure 2 3 S4 Glass Tube Level Gauge 2 4 S5 Figure 2 4 S5 Glass Tube Level Gauge 5 5 Unpacking and Inspection 5 1 5 1 Unpacking Inspection Notice 5 1 1 3...

Page 10: ...1 Check whether the product nameplate Figure 3 is consistent with the supply list information 3 Figure Product Nameplate 5 1 2 5 1 2 According to the packing list check the quantity of each part and...

Page 11: ...onnections 6 1 2 6 1 2 Level 6 2 6 2 Installation Technical Requirements 6 2 1 6 2 1 Before installing the level gauge it is necessary to measure whether the center distance of the flange on the conta...

Page 12: ...12 16 WWW DDTOP COM 4 Figure 4 Debugging 7 1 1 4...

Page 13: ...the medium to flow into the level gauge Valve 4 7 5 2 4 7 5 Fully open the upper and lower valves of the gauge Valve 2 Valve 4 8 8 Failure Analysis and Elimination Fault Phenomenon Reason Method of E...

Page 14: ...es Valve 1 Valve 2 Valve 3 Valve 4 remove the drain plug and drain the residual medium See Figure 5 9 2 2 6 9 2 2 Remove the hexagon socket head cap screws diagonally See Figure 6 9 2 3 9 2 3 After re...

Page 15: ...ll and the end face of the glass tube is basically the same as that of the shell 9 4 2 9 4 2 Insert graphite packing ring into both ends of quartz glass tube 9 4 3 9 4 3 Install the compression body a...

Page 16: ...16 16 WWW DDTOP COM...